www.scheppach.com /
+(49)-08223-4002-99 /
+(49)-08223-4002-58
GB | 37
3. Installation of the new table inlay takes place in
reverse order.
13.3 Carbon brushes
In case of excessive sparking, have the carbon
brushes checked only by an electrical specialist. IM-
PORTANT: The carbon brushes must not be replaced
by anyone but an electrical specialist.
13.4 Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: Carbon brushes, saw blade, table in-
lays, push stick
* Not necessarily included in the scope of delivery!
14. Storing the equipment
Store the device and its accessories in a dark, dry
and frostproof place that is inaccessible to children.
The optimum storage temperature is between 5 and
30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.
15. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions. The
customer‘s mains connection as well as the ex-
tension cable used must also comply with these
regulations.
• The product meets the requirements of EN 61000-
3-11 and is subject to special connection condi-
tions. This means that use of the product at any
freely selectable connection point is not allowed.
• Given unfavourable conditions in the power supply
the product can cause the voltage to fluctuate tem
-
porarily.
• The product is intended solely for use at connec-
tion points that
a) do not exceed a maximum permitted supply im-
pedance “Z”, or
b) have a continuous current-carrying capacity of
the mains of at least 100 A per phase.
• As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets one of the two requirements,
a) or b), named above.
15.1 Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
15.2 Damaged electrical connection cable.
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors
• Kinks where the connection cable has been im-
properly fastened or routed
• Places where the connection cables have been cut
due to being driven over
• Insulation damage due to being ripped out of the
wall outlet
• Cracks due to the insulation ageing
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables of the same designation.
The printing of the type designation on the connec-
tion cable is mandatory.
If it is necessary to replace the connection cable, this
must be done by the manufacturer or their represent-
ative to avoid safety hazards.
15.3 AC motor
• The mains voltage must be 230 V.
• Extension cables up to 25 m length must have a
cross section of 1.5 mm
2
.
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate
16. Disposal and recycling
The equipment is supplied in packaging to prevent it
from being damaged in transit. The raw materials in
this packaging can be reused or recycled.
The equipment and its accessories are made of vari-
ous types of material, such as metal and plastic. De-
fective components must be disposed of as special
waste. Ask your dealer or your local council.