6
– MAINTENANCE (ROUTINE AND EXTRAORDINARY)
COD.60M12/24.A.2018
EN
THE PRESENT MANUAL BELONGS TO -
Schenker Italia
- ALL RIGHTS RESERVED
41
6. MAINTENANCE (ROUTINE AND EXTRAORDINARY)
6.1 Control of filter cleaning condition
It is very important to inspect filters condition periodically.
The following filters are present in the system:
1. Net filter (strainer)
2. Pump filter 2 (5 micron cartridge filter
– white filter housinh)
3. Active carbon filter
follow the instructions given in the table below:
OPERATION
FREQUENCY
PROCEDURE
Check and cleaning of
the strainer
Every 5 days
Visual inspection and washing
Replacing of the 5 micron
cartridge filters
Every 200 working hourse. Once
replaced the filters it is necessary
to purge the air from the system,
opening for 2-3 minutes the
depressurization valve.
Unscrew the filter housing cup
counter clockwise by using the
specific key provided
Replace the active
carbon fiber filter
Once per year
Unscrew the filter housing cup
counter clockwise by using the
specific key provided