5
– FUNCTIONING AND USE
COD.60M12/24.A.2018
EN
THE PRESENT MANUAL BELONGS TO -
Schenker Italia
- ALL RIGHTS RESERVED
36
13. Press the START button. The system stars
to pressurize and the fresh water production
begins.
Verify that no leaks occur. After about 3
minuts, push STOP button. The system
activates washing procedure automatically
amd switchs off after about 40-50 seconds.
The system is now correctly purged and it is
ready to operate normally.
5.4 Normal operating procedure
Please, be sure to perform all the following checks before proceeding normal operating procedure:
6
Verify that all plant components are connected correctly.
7
Verify the 5 micron is installed correctly.
8
Be sure the seawater inlet valve and salt water drain valve are opened (If existing).
9
Be sure the reset valve is closed (lever
orthogonal
to the body valve) and the positioner completely
unscrewed.
10 Be sure the depressurization valve is closed.
11 Be sure the fresh water pressurizing pump of the boat is on.
12 Be sure the valve on the active carbon filter is opened.
13 Be sure the fresh water tank is full enough (at least 50lt) to perform washing procedure.