MP-000022 - A
•
If the flame is yellow this indicates that it is missing air for total gas burning that is achieved
by regulating the gas and air intake (figure "B",”C”). If the window is closed, causing a small
amount of air to enter, the flame obtained will be yellow, because it will have little oxygen to
carry out the complete combustion. If the regulation of the gas-air mixture is adequate, we
get a blue flame;
•
See the table below for the characteristics of each:
Yellow flame
Blue Flame
Not enough air quantity (closed window) Satisfactory gas-air mixture
Uneven format
Even format
Cool flame
Hot flame
Carbon presence
Darck blue and light blue
It produces soot
It does not produce soot
•
In figure "D" is the pressure test point Gameco TP06 of the gas circuit, the indicated for
natural gas is 0.8 kPa and for universal LG gas it is 2.6 kPa
measured at the manifold test
point (see location of this test point on page14 detail D).
•
After connection by a licensed gas fitter using Maxitrol regulators model supplied with the
machine, Make sure all removable components are locked in position- burners, pilot/burner
covers, bars, lava rocks, set the manifold pressure to 0.8kPa.
PLACING THE SKEWERS:
• Place the skewer into the rotisserie slots, after that just sit the roller on top of the front bar;
• Installer to fully test operation of the appliance after installation.
PLACING THE GRILLS
First place the upper grill after the lower grill and finally the fat collector.
NOTE: The amount of grille varies according to the size of the machine.
Содержание LVR 350A
Страница 11: ...MP 000022 A Appliance Fixing spot drawing...
Страница 15: ...MP 000022 A ADJUSTS AND CHECKING...
Страница 19: ...MP 000022 A Caution The gas system malfunction may influence the taste of the meat ACCESSING THE BACK SIDE...
Страница 20: ...MP 000022 A A Remove screws B Remove the panels BACK VIEW...
Страница 22: ...MP 000022 A Rotisserie system electrical diagram Grilling system electrical diagram...