• The gas supply should not be restricted from the main meter to machine connection; 

• Before turning the machine on, supply the water tank by filling it up to approximately 10 cm 

from the bottom of the tray. 

 

PLACE OF INSTALLATION  

 

• The appliance should be installed 50mm clearances from other appliances & combustible 

materials.  Never  obstruct  the  top,  especially  with  furniture  or  any  other  material,  as  the 

equipment will not function properly and there is a risk of fire; 

• The appliance should be installed 50mm clearances from other appliances; 

CAUTION: Do not use in outdoor locations. Do not install and use exposed to weather. 

•  For  electrical  installation  and  recommended  a  separate  electric  circuit  with  a  5A  circuit 

breaker exclusive to the unit; 

• Always seek the assistance of a qualified professional. 

 

APPLIANCE CONNECTION  

 

•   This appliance is supplied with castors and is to be connected to a fixed gas supply via a 

flexible hose connection, a restraining chain or wire of adequate strength shall be fixed to the 

appliance and be suitable to be fixed to the wall within 50mm of each connection point.  The 

length of the chain or wire shall not exceed 80% of the length of the hose assembly.  

 

RELEVANT INFORMATION TO THE INSTALLER: 

•    

Reference picture on next page

 to see where the chain/wire must be connect 

•        Unit  is  not  supplied  with  chain/wire,  neither  a  flexible  gas  hose,  these  parts  must  be 

supplied by the professional installer. 

INSTALLER: Installer needs to supply 3/4" non kink gas hose with fittings & safety chain with 

suitable fixings to secure on wall & rear panel of appliance. 

 
 
 
 

Содержание LVR 350A

Страница 1: ...MP 000022 A Serial Number Model INSTRUCTION MANUAL FOR LVR 350A Operator Tech Manual Scheer Churrasqueiras e Acess rios Ltda...

Страница 2: ...ity of this or any other appliance WARNING Do not spray aerosols or combustible oils in the vicinity of this appliance while it is in operation SCHEER CHURRASQUEIRAS E ACESS RIOS CONGRATULATIONS You j...

Страница 3: ...07 INSTALLATION 08 PLACE OF INSTALLATION APPLIANCE CONNECTION 09 PILOTS BURNERS LIGHTING PROCEDURE 11 WATER AND GAS INSTALLATION 11 ADJUSTS AND CHECKING 14 PREVENTIVE MAINTANACE 17 REMOVING BURNERS 1...

Страница 4: ...he manufacturer reserves the right to change this manual at any time This equipment must be installed in accordance with the local regulations and codes of the destination Keep this product out of the...

Страница 5: ...ed it must be replaced by the manufacturer authorized agent TRANSPORT In order to unload the unit we recommend a truck with lift gate Check for any signs of hits drops or malfunctions with responsible...

Страница 6: ...GE The unit must be unloaded in a flat and firm place can be started the removal of the barbecue from the packaging After removing the top side front and rear cover remove the machine from the pallet...

Страница 7: ...esponding to the order at the time of purchase NOTE The skewers and accessories are shipped separately from the unit Characteristics Stainless steel AISI304 brushed or AISI430 brushed as requested and...

Страница 8: ...es of Gas Used LPG or Natural Gas as requested Gas consumption m h Gas Each burner consumes 0 3125 m h of gas per hour at a pressure of 0 8 kPa Natural Gas or 2 6kPa for LPG measured at the manifold t...

Страница 9: ...r LPG measured at the manifold test point see location of this test point on page14 detail D Installer can use suitable 3 4 gas hoses that complies with standard AS NZS1869 Class B or D If a gas hose...

Страница 10: ...ctric circuit with a 5A circuit breaker exclusive to the unit Always seek the assistance of a qualified professional APPLIANCE CONNECTION This appliance is supplied with castors and is to be connected...

Страница 11: ...MP 000022 A Appliance Fixing spot drawing...

Страница 12: ...MP 000022 A LVR 350A Frontal view A Pilot Valve B Burners adjusment valves C Safety gas valve D Ignitor E Up down grilling system switch F Water inlet valve G On off switch for the rotisserie system...

Страница 13: ...knob in release the pilot flame should continue to burn If not repeat the above step 4 Rotate the gas burners control knob to OPEN ON position 5 Allow 5 minute complete shutoff period before the appli...

Страница 14: ...e lava rocks evenly over the grid covering the entire surface Lava rocks are best changed every 2 4 weeks or washed for 2nd use when they start to break down crumble stop use Unit Length Qty Lava rock...

Страница 15: ...MP 000022 A ADJUSTS AND CHECKING...

Страница 16: ...ent of the air aeration of the burners considering Universal LPG this is the regulation provided by the manufacturer when you order Universal LPG gas In figure C is the adjustment of the air aeration...

Страница 17: ...does not produce soot In figure D is the pressure test point Gameco TP06 of the gas circuit the indicated for natural gas is 0 8 kPa and for universal LG gas it is 2 6 kPa measured at the manifold tes...

Страница 18: ...ny irregularities such as Not working or working partially If there is a problem remove the burner and clean the burner with a needle If the burner continues with the low flame check that the nozzle i...

Страница 19: ...MP 000022 A Caution The gas system malfunction may influence the taste of the meat ACCESSING THE BACK SIDE...

Страница 20: ...MP 000022 A A Remove screws B Remove the panels BACK VIEW...

Страница 21: ...MP 000022 A A Rotisserie System electrical panel B Grilling system electrical panel C Rotisserie system motor D Grilling system motor ELECTRICAL DIAGRAM...

Страница 22: ...MP 000022 A Rotisserie system electrical diagram Grilling system electrical diagram...

Страница 23: ...for the lubrication of the shaft in front and behind the gears Put the oil in an container and insert it in the holes with the barbecue turned off A Lubrication spots Always turn the machine off to l...

Страница 24: ...nes in the machine After the wash replace the stones evenly over the grill and leave the grill working for 10 minutes over low heat to make sure the stones are completely dry It is recommended to wash...

Страница 25: ...and gas In the event of possible interruption of light gas and water the entire machine is switched off until service is normalized The machine is equipped with 240V 1 4CV 50HZ motor Do not soak the...

Страница 26: ...e of an accident they can cause serious burns to the skin Do not consume alcoholic drinks or narcotic substances when using the barbecue Clean the grill after use WARRANTY During the warranty period t...

Страница 27: ...ay special attention to the instruction manual to avoid damage to products or accidents Lava rocks are not under warranty Burners and heat deflectors have 12 months warranty MAINTANACE DATE TEC DATE T...

Отзывы: