MP-000022 - A
INSTALLATION
• This installation must conform according local codes (AS/NZS 5601). In the absence of
local codes, the installation must conform to the National Fuel Gas Code, ANSI Z223.1,
Natural Gas Installation Code, CAN/CGA-B149.2, or the Propane Installation Code,
CAN/CGA-149.2. For installation under ventilation hood only. The manufacturer is not
responsible for installation. After all connections and installation is in conformity with this
manual, starting pilot/burners lighting procedure.
• Remove the Gas Barbecue from the packaging;
• The Gas Barbecue should be installed where there is air circulation;
• Make sure the Gas Grill is levelled;
• The rotating system requires 240 volt power. (Check that the voltage is correct);
• Make sure all removable components are properly secured: burners, pilot, protective cover,
bars, stones, manifold. Pressure in 0.8kpa Natural Gas or 2.6kPa for LPG measured at the
manifold test point (see location of this test point on page14 detail D).
• Installer can use suitable 3/4" gas hoses that complies with standard AS/NZS1869 Class B
or D. If a gas hose is used for connection, a suitable safety chain is to be installed that does
not exceed 80% of the length of gas hose, this chain is to be fixed securely to the appliance
& the rear wall.
• Gas installation should be done taking into account the number of burners in the Gas
Barbecue. Each burner consumes 0.3125 (m³/h) of natural gas. Therefore, the gas battery
must be made according to the flow capacity required by the burners (0.3125 m³ / h);
• Each burner corresponds to: 16.880 MJ/h.
• For installation a gas regulator gas valves must be used; for units with 1 meters there is
one gas inlet so just one valves will be used and for larger than 1 m units two gas inlets will
have in your unit so it is necessary two gas pressure regulator valves.
Notes:
• Consult the technical specifications of the barbecue and call a technician specialized in
gas; (Preferably the same as the contracted gas company);
Содержание LVR 350A
Страница 11: ...MP 000022 A Appliance Fixing spot drawing...
Страница 15: ...MP 000022 A ADJUSTS AND CHECKING...
Страница 19: ...MP 000022 A Caution The gas system malfunction may influence the taste of the meat ACCESSING THE BACK SIDE...
Страница 20: ...MP 000022 A A Remove screws B Remove the panels BACK VIEW...
Страница 22: ...MP 000022 A Rotisserie system electrical diagram Grilling system electrical diagram...