background image

MP-000022 - A 

 
 
 
 

INSTALLATION 

 

•  This  installation  must  conform  according  local  codes  (AS/NZS  5601).  In  the  absence  of 

local  codes,  the  installation  must  conform  to  the  National  Fuel  Gas  Code,  ANSI  Z223.1, 

Natural  Gas  Installation  Code,  CAN/CGA-B149.2,  or  the  Propane  Installation  Code, 

CAN/CGA-149.2.  For  installation  under  ventilation  hood  only.  The  manufacturer  is  not 

responsible  for  installation.  After  all  connections  and  installation  is  in  conformity  with  this 

manual, starting pilot/burners lighting procedure. 

• Remove the Gas Barbecue from the packaging; 

• The Gas Barbecue should be installed where there is air circulation; 

• Make sure the Gas Grill is levelled; 

• The rotating system requires 240 volt power. (Check that the voltage is correct); 

• Make sure all removable components are properly secured: burners, pilot, protective cover, 

bars, stones, manifold. Pressure in 0.8kpa Natural Gas or 2.6kPa for LPG measured at the 

manifold test point (see location of this test point on page14 detail D). 

• Installer can use suitable 3/4" gas hoses that complies with standard AS/NZS1869 Class B 

or D.  If a gas hose is used for connection, a suitable safety chain is to be installed that does 

not exceed 80% of the length of gas hose, this chain is to be fixed securely to the appliance 

& the rear wall. 

•  Gas  installation  should  be  done  taking  into  account  the  number  of  burners  in  the  Gas 

Barbecue.  Each  burner  consumes  0.3125  (m³/h)  of  natural  gas.  Therefore,  the  gas  battery 

must be made according to the flow capacity required by the burners (0.3125 m³ / h); 

• Each burner corresponds to: 16.880 MJ/h. 

• For installation a gas regulator gas valves must  be used; for  units with 1 meters there is 

one gas inlet so just one valves will be used and for larger than 1 m units two gas inlets will 

have in your unit so it is necessary two gas pressure regulator valves.   

 

Notes: 

 

•  Consult  the  technical  specifications  of  the  barbecue  and  call  a  technician  specialized  in 

gas; (Preferably the same as the contracted gas company); 

Содержание LVR 350A

Страница 1: ...MP 000022 A Serial Number Model INSTRUCTION MANUAL FOR LVR 350A Operator Tech Manual Scheer Churrasqueiras e Acess rios Ltda...

Страница 2: ...ity of this or any other appliance WARNING Do not spray aerosols or combustible oils in the vicinity of this appliance while it is in operation SCHEER CHURRASQUEIRAS E ACESS RIOS CONGRATULATIONS You j...

Страница 3: ...07 INSTALLATION 08 PLACE OF INSTALLATION APPLIANCE CONNECTION 09 PILOTS BURNERS LIGHTING PROCEDURE 11 WATER AND GAS INSTALLATION 11 ADJUSTS AND CHECKING 14 PREVENTIVE MAINTANACE 17 REMOVING BURNERS 1...

Страница 4: ...he manufacturer reserves the right to change this manual at any time This equipment must be installed in accordance with the local regulations and codes of the destination Keep this product out of the...

Страница 5: ...ed it must be replaced by the manufacturer authorized agent TRANSPORT In order to unload the unit we recommend a truck with lift gate Check for any signs of hits drops or malfunctions with responsible...

Страница 6: ...GE The unit must be unloaded in a flat and firm place can be started the removal of the barbecue from the packaging After removing the top side front and rear cover remove the machine from the pallet...

Страница 7: ...esponding to the order at the time of purchase NOTE The skewers and accessories are shipped separately from the unit Characteristics Stainless steel AISI304 brushed or AISI430 brushed as requested and...

Страница 8: ...es of Gas Used LPG or Natural Gas as requested Gas consumption m h Gas Each burner consumes 0 3125 m h of gas per hour at a pressure of 0 8 kPa Natural Gas or 2 6kPa for LPG measured at the manifold t...

Страница 9: ...r LPG measured at the manifold test point see location of this test point on page14 detail D Installer can use suitable 3 4 gas hoses that complies with standard AS NZS1869 Class B or D If a gas hose...

Страница 10: ...ctric circuit with a 5A circuit breaker exclusive to the unit Always seek the assistance of a qualified professional APPLIANCE CONNECTION This appliance is supplied with castors and is to be connected...

Страница 11: ...MP 000022 A Appliance Fixing spot drawing...

Страница 12: ...MP 000022 A LVR 350A Frontal view A Pilot Valve B Burners adjusment valves C Safety gas valve D Ignitor E Up down grilling system switch F Water inlet valve G On off switch for the rotisserie system...

Страница 13: ...knob in release the pilot flame should continue to burn If not repeat the above step 4 Rotate the gas burners control knob to OPEN ON position 5 Allow 5 minute complete shutoff period before the appli...

Страница 14: ...e lava rocks evenly over the grid covering the entire surface Lava rocks are best changed every 2 4 weeks or washed for 2nd use when they start to break down crumble stop use Unit Length Qty Lava rock...

Страница 15: ...MP 000022 A ADJUSTS AND CHECKING...

Страница 16: ...ent of the air aeration of the burners considering Universal LPG this is the regulation provided by the manufacturer when you order Universal LPG gas In figure C is the adjustment of the air aeration...

Страница 17: ...does not produce soot In figure D is the pressure test point Gameco TP06 of the gas circuit the indicated for natural gas is 0 8 kPa and for universal LG gas it is 2 6 kPa measured at the manifold tes...

Страница 18: ...ny irregularities such as Not working or working partially If there is a problem remove the burner and clean the burner with a needle If the burner continues with the low flame check that the nozzle i...

Страница 19: ...MP 000022 A Caution The gas system malfunction may influence the taste of the meat ACCESSING THE BACK SIDE...

Страница 20: ...MP 000022 A A Remove screws B Remove the panels BACK VIEW...

Страница 21: ...MP 000022 A A Rotisserie System electrical panel B Grilling system electrical panel C Rotisserie system motor D Grilling system motor ELECTRICAL DIAGRAM...

Страница 22: ...MP 000022 A Rotisserie system electrical diagram Grilling system electrical diagram...

Страница 23: ...for the lubrication of the shaft in front and behind the gears Put the oil in an container and insert it in the holes with the barbecue turned off A Lubrication spots Always turn the machine off to l...

Страница 24: ...nes in the machine After the wash replace the stones evenly over the grill and leave the grill working for 10 minutes over low heat to make sure the stones are completely dry It is recommended to wash...

Страница 25: ...and gas In the event of possible interruption of light gas and water the entire machine is switched off until service is normalized The machine is equipped with 240V 1 4CV 50HZ motor Do not soak the...

Страница 26: ...e of an accident they can cause serious burns to the skin Do not consume alcoholic drinks or narcotic substances when using the barbecue Clean the grill after use WARRANTY During the warranty period t...

Страница 27: ...ay special attention to the instruction manual to avoid damage to products or accidents Lava rocks are not under warranty Burners and heat deflectors have 12 months warranty MAINTANACE DATE TEC DATE T...