Instruction Manual for Electroblock EBL 252
12
Date: 23.01.2020
8110253 BA / EN
D Block diagram
Consumer 1
SB
WB
Consumer 2
Pump
Minifit SR 4F -- block 1
LR ...
HS Rel2 On
Circuit board KPL EBL 251
MNL socket cap 12F -- block 6
MNL socket cap 9F -- block 4
Steady plus
TV
Pump switch
nc
Mains indicator
Plug connector MSFQ/O 12F -- block 7
nc
MNL socket cap 2F -- block 3
+ leisure battery (batt. 2)
Leisure battery negative
+ sensor, leisure battery (batt. 2)
Negative sensor leisure battery (batt. 2)
12V indicator
+ Starter battery (batt. 1)
12V ON
12V OFF
Water tap (input)
Awning light
Step
Heater
+ batt. 1 for refrigerator *
Negative batt. 1 for
MNL socket
Negative, refrigerator
D+ point
Charging relay
Starter battery
Auxiliary charger
Leisure battery negative must be
starter battery negative.
Battery
cut--off relay
+ Starter battery (batt. 1)
HS relay 1
(60A)
Fridge
Refrigerator lines
must be routed separately
from other battery
lines to the
battery terminals.
*
Permanent
12V
Solar
charge regulator
Solar module
Switching stage
Mains 230V~50Hz
IEC connector
Changeover switch
Lead--acid
AGM
Relay
+ Refrigerator
Negative sensor leisure battery
+ sensor, leisure battery
D+ input
MNL socket cap 4F -- block 5
refrigerator *
D+ point
Important:
Only use fuse
for compressor
Aux. 50W heater
3F block 2
Consumer 3
--
HS relay 2
(60A)
HS Rel2 Off
refrigerator
coonected externally