Operating Instructions Electroblock EBL 211

15

Date: 22.01.2016

9110476 BA / EN

E

Block diagram/wiring diagram

230 V mains ~ 50 Hz
Low power device socket

230V AC

LAS 1218

S

1218

Changeover
switch
Lead-gel
AGM

Charging relay B1

Main
switch-rel
ay

Batterycut--off relay

Battery-
monitor
BW 208

Switching stage

Refrigerator

Important

The fuse is only used
for an AES refrigerator

Awningl
ight

Circuit board KPL EBL 208

Battery on / off

Battery cut--out switch:
Isolates the control panel and the frost protection valve of the
heater system from the battery to prevent standby currents during
shut--down.
Plug connector LF--PA 401
6.3x0.8 -- 4x 6-way

+ Leisure area battery

+ Starter battery
D+ input
D+ point

+ sensor, leisure area battery
Negative leisure area battery sensor
Negative, leisure area battery*
Negative, leisure area battery*

+ Starter battery
Shunt battery
Shunt consumer
+ sensor, leisure area battery
Mains indicator

12V On
12V Off
Negative leisure area battery sensor
12 V indicator
Pump switch

Lumberg MSFQ/0 10--way

+ Frost protection valve
Connected negative terminal of pump

+ Pump

Negative SB for refrigerator
Negative, refrigerator
+ refrigerator

+ SB for refrigerator

+ Awning light
+ Heater
+ Light 1
+ Light 2

+ Spare
+ Light 3
+ Step

MNL 3--way socket housing

+ WB
--
+ SB

Solar-
charge regulator

SB: Starter battery
WB: Leisure area battery

* The negative terminals for leisure area

and starter batteries must be connected
to each other externally.

Содержание Electroblock EBL 211

Страница 1: ...ormation 2 1 1 Meaning of safety symbols 2 1 2 General safety information 2 1 3 Liability limitation 3 2 Introduction 3 3 Operation 4 3 1 Switching system on and off 4 3 2 Changing the battery 5 3 3 Operating faults 6 3 4 Shutting down 7 4 Application and functions in detail 9 4 1 General 9 4 2 Battery functions 10 4 3 Additional functions 10 5 Technical details 11 5 1 Mechanical details 11 5 2 El...

Страница 2: ... device must be repaired immediately by specialists Y DANGER Parts carry 230V mains voltage Risk of fatal injury due to electric shock or fire F Do not carry out maintenance or repair work on the device F If cables or the device housing are damaged no longer use the device and isolate it from the power supply F Ensure that no liquids enter the device F The mains connection line may only be replace...

Страница 3: ...stalla tion guide F improper assembly and or installation F non intended use F improper repairs F technical modifications F use of unapproved spare parts 2 Introduction This instruction manual contains important information for the safe operation of equipment supplied by Schaudt Make sure you read and follow the safety instructions provided The operating instructions should always be kept in the v...

Страница 4: ...le Deactivate the battery cut out shutdown as required refer to Section 3 4 Use the main 12 V switch see instruction manual of relevant control and switch panel to switch on off all the consumers and the control and switch panel Exceptions F Step F Frost protection valve F AES refrigerator Please refer to the operating instructions for the operator and control panel for further information Y ATTEN...

Страница 5: ...r also to Section 3 4 Remove solar cell connector on the solar charge regulator if availa ble Isolate the electroblock from the mains voltage 230V AC Replace the battery After changing the battery recheck which type of battery has been inser ted Y DANGER Incorrect setting of the battery selector switch Risk of explosion due to build up of explosive gases F Move the battery selector switch to the c...

Страница 6: ... on the automatic fuse in the vehicle g g operation battery voltage constantly below 13 3 V Have the mains voltage constantly below 13 3 V Have the mains voltage checked Defective electroblock Contact customer service Leisure area battery is overcharged during 230 V operation battery voltage constantly above 14 5 V Defective electroblock Contact customer service Starter battery is not char No main...

Страница 7: ...rom Defective electroblock Contact customer service block not possible from the control panel Y The charging current is reduced automatically if the device becomes too hot due to excessive ambient temperature or lack of ventilation Always prevent the device from overheating nevertheless Y If the automatic shutdown mechanism of the battery monitor is triggered fully charge the leisure area battery ...

Страница 8: ...sure area battery is isolated from the electroblock via the battery cut out The boiler and water tank empty when the frost protection valve is open See the instruction manual for the heater system for further information The leisure area battery is also charged by the internal charger module an additional battery charger the solar charger regulator and the alterna tor when the battery cut out is a...

Страница 9: ...r etc 12V consumers Starter battery Leisure area battery Fig 2 On board power supply system The EBL 211 electroblock comprises F a charge module for charging all batteries connected F the complete 12V distribution unit F the fuses for the 12V circuits F a main switch module F battery monitor F other control and monitoring functions A control and switch panel must be connected for operation This de...

Страница 10: ... leisure area battery causes the voltage to fall so low that the automatic disconnector is triggered any non essential consumers should be switched off It may be the case that only the 12 V supply is started for a short time For this switch on the 12V main switch on the control and switch panel However if the battery voltage remains below 11 0 V you cannot switch the 12 V power supply back on Full...

Страница 11: ...2 6 V battery voltage F Battery alarm OFF F Battery cut out switch ON F Lighting for operator and control panel OFF F All consumers switched off F 12 V main switch OFF Loading of D output of the alternator by the electroblock approx 0 5 mA without current consumption on D point 12 V outputs A maximum of 90 of the nominal current of the relevant fuse may be drawn Frost protection valve output max 0...

Страница 12: ...duration of the full charge phase is based on the battery type and is set on the device U Automatic changeover to compensation charge with constant 13 7 V In the compensation charge phase the voltage at the output of the char ging module is constant Start of a new charging cycle by switching over to main charge if the battery voltage falls below 13 7 V for more than 5 seconds when loaded Start of ...

Страница 13: ...ienst schaudt gmbh de Returning a faulty device Complete and enclose the fault report see Appendix C Send it to the addressee free delivery C Fault report In the event of damage please fill in the fault report and send it with the faulty device to the manufacturer Device type _______________________ Item no _______________________ Vehicle Manufacturer _______________________ Model ________________...

Страница 14: ...panel 2 Battery switchover types gel AGM 3 Flat vehicle fuse for AES refrigerator 4 Flat vehicle fuses for consumers 5 Battery cut out 6 Step fuse 7 Flat vehicle fuse for solar regulator 8 Mains connection 9 Housing 10 Connection block solar regulator supply 11 6 3 mm consumer connectors 12 Connector block for batteries 13 Device feet 1 Fig 5 Layout of EBL 211 electroblock rear 1 Cover ...

Страница 15: ...or LF PA 401 6 3x0 8 4x 6 way Leisure area battery Starter battery D input D point sensor leisure area battery Negative leisure area battery sensor Negative leisure area battery Negative leisure area battery Starter battery Shunt battery Shunt consumer sensor leisure area battery Mains indicator 12V On 12V Off Negative leisure area battery sensor 12 V indicator Pump switch Lumberg MSFQ 0 10 way Fr...

Страница 16: ...Operating Instructions Electroblock EBL 211 16 Date 22 01 2016 9110476 BA EN Blank page ...

Отзывы: