Schaudt Electroblock EBL 211 Скачать руководство пользователя страница 10

Operating Instructions Electroblock EBL 211

10

Date: 22.01.2016

9110476 BA / EN

4.2

Battery functions

6-cell AGM or lead-gel batteries, 55 Ah and above

The battery cut-out (at the battery cut-out switch of the electroblock, see Fig.

4, Pos. 15, see also Section 3.4) isolates the following connections from the

leisure area battery:

F

all 12 V consumers

F

the frost protection valve

This prevents slow discharge of the leisure area battery by the standby cur-

rent during shutdown of the vehicle (discharge with approx. 4 Ah in month).

The batteries can still be charged using the electroblock, the alternator, an

auxiliary charging unit or the solar charge regulator, even when the battery

cut-out switch is switched off.

The switching option provided by the battery selector switch ensures opti-

mum charging of the two battery types, lead-gel and AGM.

The battery monitor compares the voltage of the leisure area battery with a

reference voltage. As soon as the battery voltage falls below 10.5 V, all 12 V

consumers are switched off. Only the step, the frost protection valve and the

AES refrigerator are still powered. The automatic disconnector is not trigge-

red by short-term low voltage (shorter than 2 seconds), caused by high cur-

rent when switching on consumers.

If an overload or an insufficiently charged leisure area battery causes the

voltage to fall so low that the automatic disconnector is triggered, any non-

essential consumers should be switched off.

It may be the case that only the 12 V supply is started

for a short time. For this, switch on the 12V main switch on the control and

switch panel.

However, if the battery voltage remains below 11.0 V, you cannot switch the

12 V power supply back on.

Fully charge the leisure area battery as soon as possible. For more informa-

tion, see the description of ”battery voltages”.

4.3

Additional functions

This relay supplies the AES/compressor refrigerator with power from the

starter battery when the vehicle engine is running and the D+ connection is

live. An AES/compressor refrigerator is powered by the leisure area battery

when the vehicle engine is not running.

The ”Step” output is fused with a 15 A fuse and is supplied continually, even

when the main 12 V switch is OFF.

Maximum permitted charge current 14 A, protected with 15 A

Depending on the solar charge regulator used, either only the leisure area

battery is charged or the leisure area battery and the starter battery.

The awning light only works when the power supply is on, the vehicle engine

is off and the D+ connection is not live.

Suitable batteries

Battery cut-out

Battery selector switch

Battery monitor with

automatic disconnect

Automatic switch

function for

AES/compressor

refrigerator

Step fuse

Battery charging with

solar charging regulator

Automatic switch

function for awning light

Содержание Electroblock EBL 211

Страница 1: ...ormation 2 1 1 Meaning of safety symbols 2 1 2 General safety information 2 1 3 Liability limitation 3 2 Introduction 3 3 Operation 4 3 1 Switching system on and off 4 3 2 Changing the battery 5 3 3 Operating faults 6 3 4 Shutting down 7 4 Application and functions in detail 9 4 1 General 9 4 2 Battery functions 10 4 3 Additional functions 10 5 Technical details 11 5 1 Mechanical details 11 5 2 El...

Страница 2: ... device must be repaired immediately by specialists Y DANGER Parts carry 230V mains voltage Risk of fatal injury due to electric shock or fire F Do not carry out maintenance or repair work on the device F If cables or the device housing are damaged no longer use the device and isolate it from the power supply F Ensure that no liquids enter the device F The mains connection line may only be replace...

Страница 3: ...stalla tion guide F improper assembly and or installation F non intended use F improper repairs F technical modifications F use of unapproved spare parts 2 Introduction This instruction manual contains important information for the safe operation of equipment supplied by Schaudt Make sure you read and follow the safety instructions provided The operating instructions should always be kept in the v...

Страница 4: ...le Deactivate the battery cut out shutdown as required refer to Section 3 4 Use the main 12 V switch see instruction manual of relevant control and switch panel to switch on off all the consumers and the control and switch panel Exceptions F Step F Frost protection valve F AES refrigerator Please refer to the operating instructions for the operator and control panel for further information Y ATTEN...

Страница 5: ...r also to Section 3 4 Remove solar cell connector on the solar charge regulator if availa ble Isolate the electroblock from the mains voltage 230V AC Replace the battery After changing the battery recheck which type of battery has been inser ted Y DANGER Incorrect setting of the battery selector switch Risk of explosion due to build up of explosive gases F Move the battery selector switch to the c...

Страница 6: ... on the automatic fuse in the vehicle g g operation battery voltage constantly below 13 3 V Have the mains voltage constantly below 13 3 V Have the mains voltage checked Defective electroblock Contact customer service Leisure area battery is overcharged during 230 V operation battery voltage constantly above 14 5 V Defective electroblock Contact customer service Starter battery is not char No main...

Страница 7: ...rom Defective electroblock Contact customer service block not possible from the control panel Y The charging current is reduced automatically if the device becomes too hot due to excessive ambient temperature or lack of ventilation Always prevent the device from overheating nevertheless Y If the automatic shutdown mechanism of the battery monitor is triggered fully charge the leisure area battery ...

Страница 8: ...sure area battery is isolated from the electroblock via the battery cut out The boiler and water tank empty when the frost protection valve is open See the instruction manual for the heater system for further information The leisure area battery is also charged by the internal charger module an additional battery charger the solar charger regulator and the alterna tor when the battery cut out is a...

Страница 9: ...r etc 12V consumers Starter battery Leisure area battery Fig 2 On board power supply system The EBL 211 electroblock comprises F a charge module for charging all batteries connected F the complete 12V distribution unit F the fuses for the 12V circuits F a main switch module F battery monitor F other control and monitoring functions A control and switch panel must be connected for operation This de...

Страница 10: ... leisure area battery causes the voltage to fall so low that the automatic disconnector is triggered any non essential consumers should be switched off It may be the case that only the 12 V supply is started for a short time For this switch on the 12V main switch on the control and switch panel However if the battery voltage remains below 11 0 V you cannot switch the 12 V power supply back on Full...

Страница 11: ...2 6 V battery voltage F Battery alarm OFF F Battery cut out switch ON F Lighting for operator and control panel OFF F All consumers switched off F 12 V main switch OFF Loading of D output of the alternator by the electroblock approx 0 5 mA without current consumption on D point 12 V outputs A maximum of 90 of the nominal current of the relevant fuse may be drawn Frost protection valve output max 0...

Страница 12: ...duration of the full charge phase is based on the battery type and is set on the device U Automatic changeover to compensation charge with constant 13 7 V In the compensation charge phase the voltage at the output of the char ging module is constant Start of a new charging cycle by switching over to main charge if the battery voltage falls below 13 7 V for more than 5 seconds when loaded Start of ...

Страница 13: ...ienst schaudt gmbh de Returning a faulty device Complete and enclose the fault report see Appendix C Send it to the addressee free delivery C Fault report In the event of damage please fill in the fault report and send it with the faulty device to the manufacturer Device type _______________________ Item no _______________________ Vehicle Manufacturer _______________________ Model ________________...

Страница 14: ...panel 2 Battery switchover types gel AGM 3 Flat vehicle fuse for AES refrigerator 4 Flat vehicle fuses for consumers 5 Battery cut out 6 Step fuse 7 Flat vehicle fuse for solar regulator 8 Mains connection 9 Housing 10 Connection block solar regulator supply 11 6 3 mm consumer connectors 12 Connector block for batteries 13 Device feet 1 Fig 5 Layout of EBL 211 electroblock rear 1 Cover ...

Страница 15: ...or LF PA 401 6 3x0 8 4x 6 way Leisure area battery Starter battery D input D point sensor leisure area battery Negative leisure area battery sensor Negative leisure area battery Negative leisure area battery Starter battery Shunt battery Shunt consumer sensor leisure area battery Mains indicator 12V On 12V Off Negative leisure area battery sensor 12 V indicator Pump switch Lumberg MSFQ 0 10 way Fr...

Страница 16: ...Operating Instructions Electroblock EBL 211 16 Date 22 01 2016 9110476 BA EN Blank page ...

Отзывы: