3.8.  Setting Off-Mode 2 (with micro switch or switch) - Standard for type GU 

(Upper end position about torque detection / set end position bottom) 

Step No. 

Operation 

Note 

Check 

 

Important:

 

-  First, there must always be taught the upper end position. 
-  If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be 
  set into learning mode again. 

10  

 

Setting the upper end position  
 

Press UP-Button, 
until the upper end position is reached and switches off auto-
matically about the torque detection. Keep pressing the button for 
at least 1 sec. longer after switching off. 
 

20  

 

 

Setting the lower end position  

 
Press DOWN-button,  

until the desired lower end position is reached. 

 
Only for type GU 

with foamed slats: 

 

-  Hangers lie outside

 (right roller shutter) or 

at 

the window (left 

rolling shutter) 

the spring has no pressure yet. 

Final rail is on the ground, light slits are closed, if they 
exist. 

 
Moving back or moving in short impulses is allowed. 

 

30 

 

 

 

 

 

First press the micro switch and then the active button for ca. 2 sec. in order to learn the upper 
position. As a learning confirmation it twitches twice. 
 

Attention:

 Pressing the buttons not long enough the position will not be learned. 

 

The setting mode is exited.

 

 

The learning of the forces happens automatically when running continuously from one end position to the other. 
Perform this first test run only after completing all installation. 

3.9.  Setting Off-Mode 3 (with test cable) 

(Set end position at the top / lower end position about torque detection) 

Step No. 

Operation 

Note 

Check 

 

Important:

 

-  First, there must always be taught the upper end position. 
-  If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be 
  set into learning mode again. 

10  

 

Setting the upper end position  

 
Press UP-Button, 
until the shutter is in the desired upper end position. However it 
has to stand stable within the guiding so that it does not leave it 
when changing the winding behaviour. 
 
Moving back or moving in short impulses is allowed. 

20 

 

 

 

Press both buttons simultaneously or the programming button* for ca. 2 sec. in order to learn the 
upper position. As a learning confirmation it twitches twice. 
 

Attention:

 Pressing the buttons not long enough the position will not be learned. 

 
 

      *Depending 

on 

test 

cable 

model 

Содержание Studio Star

Страница 1: ...Motor Studio Star This Operating Instruction contains important safety instructions For the safety of persons it is important to follow these instructions This instruction should be kept Schanz Rolll...

Страница 2: ...de 3 9 3 4 Overview Off Mode 4 9 3 5 Setting Off Mode 1 with test cable 10 3 6 Setting Off Mode 1 with micro switch and switch 10 3 7 Setting Off Mode 2 with test cable Standard for type GU 11 3 8 Set...

Страница 3: ...e roller shutter for the first time as the drive is in learning mode upon delivery Depending on test cable model 1 2 Setting with micro switch and switch Step No Operation Note Check The motor is deli...

Страница 4: ...m the up per end position 2 2 Overview Off Mode 2 For all types with box on bottom Upper end position about torque detection shutter moves against the stop set end position bottom An end position read...

Страница 5: ...int it has to be set into learning mode again 10 Setting the upper end position Press UP Button until the upper end position is reached and switches off auto matically about the torque detection Keep...

Страница 6: ...e endpoint it has to be set into learning mode again 10 Setting the upper end position Press UP Button until the upper end position is reached and switches off auto matically about the torque detectio...

Страница 7: ...cally about the torque detection Keep pressing the button for at least 1 sec longer after switching off 20 Setting the lower end position Press DOWN Button until the desired position is reached The en...

Страница 8: ...switches off auto matically about the torque detection Keep pressing the button for at least 1 sec longer after switching off 20 Setting the lower end position Press DOWN Button until the desired pos...

Страница 9: ...d for type GU Upper end position about torque detection shutter moves against the stop set end position bottom The upper end position is being readjusted automatical ly the lower end position stays fi...

Страница 10: ...omatically when running continuously from one end position to the other Perform this first test run only after completing all installation 3 6 Setting Off Mode 1 with micro switch and switch Upper and...

Страница 11: ...er after switching off 20 Setting the lower end position Press DOWN button until the desired lower end position is reached Only for type GU with foamed slats Hangers lie outside right roller shutter o...

Страница 12: ...en the active button for ca 2 sec in order to learn the upper position As a learning confirmation it twitches twice Attention Pressing the buttons not long enough the position will not be learned The...

Страница 13: ...increase of force before reaching the endpoint it has to be set into learning mode again 10 Setting the upper end position Press UP Button until the shutter is in the desired upper end position Howev...

Страница 14: ...position As a learning confirmation it twitches twice Attention Pressing the buttons not long enough the position will not be learned Depending on test cable model 30 Setting the lower end position P...

Страница 15: ...2 sec in order to learn the upper po sition As a learning confirmation it twitches twice Attention Pressing the buttons not long enough the position will not be learned 30 Setting the lower end posit...

Страница 16: ...stitutions and spread without our written agreement nor should it be used for other pur poses The containing information in this document makes no claim to be complete We have done everything to refle...

Отзывы: