NBS – Fan coil unit
TECHNICAL DOCUMENTATION
Order code PL-NBS
Construction subject to change.
No return possible.
Version: 06.05.21 | Page 36
ORDER CODE PL-NBS
01
02
03
04
05
06
07
Type
Family
Model
Size
Model
Length
Insulation
Example
PL
-NBS
-100
-1
-Z
-0500
-I0
08
09
10
Connection in
air flow
direction
Connection in air
flow direction on
the left
Connection in air
flow direction on
the right
Example
-MAB
-L00
-R00
NOTE
Please always specify the complete order code in the order!
If details are missing from the order, the standard model will be delivered.
Any special model not included in the order code must be queried before ordering.
* = if no details are given, processing is impossible.
EXAMPLE
PL-NBS-100-1-Z-0500-I0-MAB-L00-R00
Plenum box | for room air conditioning module NBS | for product NBS-100 | size 1 | supply air box | length 500 mm | without insulation |
connection open in air flow direction | connection closed in air flow direction on the left | connection closed in air flow direction on the right
ORDER DETAILS
1 – Type
PL =
Plenum box
2 – Family
NBS =
for room air conditioning module NBS
3 – Model*
100 =
for product NBS-100
150 =
for product NBS-150
4 – Size*
1 =
Size 1
2 =
Size 2
3 =
Size 3
5 – Model
Z =
supply air box (standard)
A =
return air box
6 – Length
xxxx =
length xxxx mm (from 0300 to 1000, always with 4
digits in mm)
0500 =
length 500 mm (standard)
7 – Insulation
I0 =
without insulation (standard)
I1 =
thermal insulation of 10 mm
I2 =
sound and thermal insulation of 20 mm
I4 =
sound and thermal insulation of 40 mm (not
compatible with spigots >DN123)
8 – Connection in air flow direction*
M00 =
connection closed in air flow direction
MAB =
connection open in air flow direction
MRE =
connecting flange in air flow direction
M1x =
with x spigot DN123 in air flow direction
M2x =
with x spigot DN158 in air flow direction
M3x =
with x spigot DN198 in air flow direction
M4x =
with x spigot DN248 in air flow direction
---
(for the number of spigots, see table)
9 – Connection in air flow direction on the left*
L00 =
connection closed in air flow direction on the left
L1x =
with x spigot DN123 in air flow direction on the left
L2x =
with x spigot DN158 in air flow direction on the left
L3x =
with x spigot DN198 in air flow direction on the left
L4x =
with x spigot DN248 in air flow direction on the left
---
(for the number of spigots, see table)
10 – Connection in air flow direction on the right*
R00 =
connection closed in air flow direction on the right
R1x =
with x spigot DN123 in air flow direction on the right
R2x =
with x spigot DN158 in air flow direction on the right
R3x =
with x spigot DN198 in air flow direction on the right
R4x =
with x spigot DN248 in air flow direction on the right
---
(for the number of spigots, see table)