![Schaerer Coffee Celebration BCL Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/schaerer/coffee-celebration-bcl/coffee-celebration-bcl_operating-instructions-manual_1209830008.webp)
www.schaerer.com
Product description
8 / 50
Operating instructions / V07 / 08.2011
Power supply
Model
Power rating
Fuse
(installation
site)
Connection cable
conductor cross-
section
SCC BCL Europa
380-415V 3NAC 50/60Hz
8500-10100W
3 x 16A
5 x 1.5mm
2
3000-3400W
220-240V AC
50Hz
5800-6900W
3 x 16A
5 x 1.5mm
2
1 x 30A
3 x 4mm
2
SCC BCL Korea
400V 3NAC 50/60Hz
10200W
3 x 16A
5 x 1.5mm
2
SCC BCL Japan,
Saudi-Arabien,
Norwegen-Netz B
200-220V 3AC
50/60Hz
7400-8400W
2 x 30A
4 x 10AWG
5000-5700W
The device must be electrically connected according to all valid regulations (VDE 0100) as well as national
stipulations. Design of network implementation line, at least H05 VV-F, harmonized. The voltage specified
on the serial plate must match the supply voltage at the installation location.
►
All poles of the device must be able to be disconnected from the power supply.
► Never operate a device with a faulty power cord. Have a defective power cord or plug replaced imme
-
diately by a qualified service technician.
►
Schaerer Ltd. advises against the use of extension cables!sion cables!
If an extension cable
must be used, nevertheless (minimum cross-section: 1.5 mm2), please observe the cable manufac-
turer’s data (instructions for use) and all local regulations.
► Power cords must be connected in such a way that no one can trip over them. Do not pull the cords
over corners or sharp edges, pinch them between objects or allow them to hang loosely in a room. Do
not place cables over hot objects, and protect them from oil and aggressive cleaning agents.
► Never lift or pull the device by its power cord. Never pull the plug out of the socket by its cord. Never
touch the power cord or plug with wet hands! Never insert a wet plug into a power socket!
The phase must be protected from short-circuits with 16A / 30 A (Ampère)!
Water connection / draining
The water supply must be connected according to all valid regulations as well as national stipula-tions. If
the machine is connected to a newly installed water pipe, the pipe and the supply tube must be thoroughly
rinsed so that no dirt particles can enter the machine. The coffee maker must be connected to an installed
drinking-water pipe with shutoff valve. The machine is installed by using the mounted pressure tube and
the G 1/2“ screw at the pressure relief component mounted to the tap (set to 3 bar). If the machine is at-
tached to a water drainage system, the supplied temperature-resistant drain hose must be connected to
the drip try and siphon. It must be firmly attached to the drain and slanted at a downward angle (so that the
water can flow downward).
Always use the new hoses supplied with the machine (fresh-/drain water hose)! Do not use old
fresh- and drain water hoses!
The water must be
free of contaminants
and the chlorine content may not exceed
100 mg/l
. Do not use
pure
reverse osmosis
(RO) water or any other type of
aggressive
water. The carbonate hardness may
not exceed
5 – 6°dKH
(German carbonate hardness) or
8 – 10°fKH
(French carbonate hardness) and
the total hardness must be always higher than the carbonate hardness. The minimal carbonate hardness
is
4°dKH
or
7°fKH
. The pH value must be between
6.5 – 7
.
Water inlet pressure
Recommended:
0.1 MPa – 0.3 MPa (1 – 3 bar)
Maximum:
0.6 MPa (6 bar)
Wassereingangstemperatur
Minimum:
10 °C
Maximum:
30 °C
We recommend setting the pressure relief valve to 3 bar!