www.schaerer.com
Safety notes
50 / 50
Operating instructions / V07 / 08.2011
Intended use
The Schaerer Coffee Celebration has been designed to dispense coffee beverages and/or milk beverages
in different versions – in cups or coffeepots. Additionally, the unit can supply steam for heating up milk and/
or hot water. This unit is designed for industrial and commercial use. The unit may be placed in self-service
areas if attended to by trained personnel.
Use of this equipment is subject to the “General Terms and Conditions” of Schaerer Ltd. and these operat-
ing instructions. In legal terms, any other use is not an intended use. The manufacturer accepts no liability
for damage resulting from unintended use.
The Schaerer Coffee Celebration may not under any circumstances be used to heat up or dispense
any other liquids than coffee, hot water (for beverages or cleaning) or milk (cooled, pasteurised,
homogenised, UHT).
Liability
No responsibility will be taken for warranty or liability claims in the event of personal injury or material dam
-
age as a result any or all of the following causes.
Cleaning:
►
Thoroughly wash and disinfect hands before and after cleaning the machine!
► Clean the machine daily once beverage output has been completed.
► For daily and weekly cleaning, follow the steps in the Operating instructions (chapter "
Cleaning
") and
on the cleaning card.
► Never mix cleaning products!
► Never use abrasive substances or cleaning tools made of metal!
► Do not touch parts that come into contact with beverages (during or before output) after they have been
cleaned.
► Follow the dosage and safety instructions on the cleaning product! Information about cleaning prod
-
ucts can be found in the Operating instructions, chapter "
Appendix
".
► If the machine is equiped with a the refrigerator / cooling unit (optional) this must be cleaned at least
once a week!
►
Improper use of the device.
► Improper installation, commissioning, operation and/or servicing of the device and its corresponding
options.
► Non-observance of recommended maintenance intervals.
► Operation of the device with defective safety devices, non-functioning safety devices or improperly at
-
tached protective devices.
► Non-observance of safety notes in the Operating instructions with respect to storing, installing, com
-
missioning, operating and servicing the machine.
► Operation of the device in less than optimal condition.
► Improperly conducted repairs.
► If replacement / spare parts used are not original spare parts by
Schaerer Ltd.
;
► If cleaning agents other than those recommended by
Schaerer Ltd.
have been used;
► Emergencies or failures due to the effects of a foreign body, accident or vandalism as well as acts of God.
► Insertion of objects into the device as well as opening of the housing.
►
Schaerer Ltd.
must be notified in writing immediately of any material flaws!
► The device must be serviced every
12 months
or after
70'000
products have been dispensed, which
ever is earlier.
Safety-relevant parts such as safety valves, safety thermostats, boilers, etc.
must never be repaired
under any circumstances
. They must be replaced as follows:
► Safety valves every
12 months
► Boiler (steam boiler, flow heater) every
60 months
The manufacturer only accepts liability or honnors warranty claims provided that all specified maintenance
and service intervals have been abserved and that only original spare parts supplied by the manufacturer
or an approved authorized supplier have been used.