7
September 2006
2-2-3 RS-232C:
Connect to remote control unit (optional accessory) or connect to computer for
remote control working status
.
2-2-4 Connect chassis ground terminal to earth or to vehicle chassis using # 8 AWG wire.
2-3 Installation:
Where to install:
The power inverter should be installed in a location that meets the following requirements:
2-3-1 Dry: Do not allow water to drip or splash on the inverter.
2-3-2 Cool: Ambient air temperature should be between 0C and 40C.
2-3-3 Safe: Do not install in a battery compartment or other areas where flammable fumes
may exist, such as fuel storage areas or engine compartments.
2-3-4 Ventilated: Allow at least three inches of clearance around the inverter for air flow,
ensuring that the ventilation openings on the rear and bottom of the unit are not
obstructed.
WARNING!
Do not connect the 12VDC model to a 24VDC battery.
The unit will be destroyed immediately!
WARNING!
Operation of the inverter without a proper ground
connection may result in an electrical safety hazard
WARNING!
Shock Hazard! Before proceeding, carefully check the
AEP-700 inverter is NOT connected to any batteries and is
disconnected from any electrical source. Do not connect
the output terminals of the AEP-700 to an incoming source
at this time.
Содержание AEP-700-121