13
September 2006
The accuracy of the six display functions is below:
Functions
VAC
AMP WATT
VDC
TEMP Frequency
Ranges
100-120
VAC
200-240
VAC
0-10A 0-1KW
10-16
VDC
20-32
VDC
42-62
VDC
0-120
50Hz
60Hz
Accuracy
± 1%
± 1%
± 1%
± 3%
± 2%
± 2%
± 2%
± 1%
±0.01
±0.01
2-7-8 Over Voltage Protection Indicator: (OVP)
The over voltage indicator indicates that the power inverter has shut itself down
because its input voltage exceeded the limits of the inverter (see Page 12).
2-7-9 Under Voltage Protection Indicator: (UVP)
The under voltage indicator indicates that the power inverter has shut itself down
because its input voltage fell below the limits of the inverter (see Page12).
2-7-10 Over Temperature Protection Indicator: (OTP)
The over temperature indicator indicates that the power inverter has shut itself
down because the inverter has overheated. The power inverter may overheat
because it has been operated at power levels above its rating or because it has
been installed in a location which does not allow it to dissipate heat properly. The
power inverter will automatically restart, once the temperature has decreased.