September 2006

AEP-700 Series

Pure Sine Wave Inverter

  User Manual

200 Butterfield Drive, Ashland, MA 01721, Tel: (508)881-7330, Fax: (508)231-0861

Website: http://www.schaeferpower.com   Email: [email protected]

Содержание AEP-700-121

Страница 1: ...ptember 2006 AEP 700 Series Pure Sine Wave Inverter User Manual 200 Butterfield Drive Ashland MA 01721 Tel 508 881 7330 Fax 508 231 0861 Website http www schaeferpower com Email sales schaeferpower co...

Страница 2: ...7 8 2 4 Quick hook up and testing 8 9 2 5 AC safety grounding 9 2 6 Making DC wiring connections 9 11 2 7 Inverter operation 11 14 2 8 Output power 14 2 9 Cooling fan operation 15 3 Maintenance 15 4 T...

Страница 3: ...andscaping tools air compressors 1 1 2 Office equipment computers printers monitors facsimile machines scanner 1 1 3 Household items vacuum cleaners fans fluorescent and incandescent lights shavers se...

Страница 4: ...Frequency 50 60Hz 0 05 Switch Selectable Efficiency full load 88 90 91 92 94 94 No Load Current Draw 0 87A 0 43A 0 23A 0 83A 0 43A 0 22A Output Waveform Pure Sine Wave THD 3 Protection Overload Short...

Страница 5: ...4 September 2006 1 3 Mechanical Drawings...

Страница 6: ...re proper installation and use of the AEP 700 2 1 Front Panel Operation 2 1 1 Front view 2 1 2 ON OFF Switch Please keep the Power ON OFF switch in the OFF position during installation 2 1 3 Function...

Страница 7: ...peration 2 2 1 Ventilation openings Do not obstruct allow at least 3 inches for airflow 2 2 2 Battery terminals Connect to a 12VDC 24VDC 48VDC battery or other 12VDC 24VDC 48VDC power source Red is po...

Страница 8: ...other areas where flammable fumes may exist such as fuel storage areas or engine compartments 2 3 4 Ventilated Allow at least three inches of clearance around the inverter for air flow ensuring that...

Страница 9: ...sition 2 4 2 Connect the cables to the power input terminals on the rear panel of the power inverter The red terminal is positive and black terminal is negative Insert the cables into the terminals an...

Страница 10: ...nd wire should go to the grounding point for your loads for example a distribution panel of bus chassis 2 6 Making DC Wiring Connections Follow this procedure to connect the battery cables to the DC i...

Страница 11: ...end the following cables for optimum inverter performance Use only high quality copper wiring and keep cable length short from 3 6 feet Model No Wire AWG Inline Fuse AEP 700 121 4 100A AEP 700 122 4 1...

Страница 12: ...nverter turn them on separately after the inverter has been turned on This will ensure that the power inverter does not have to deliver the starting currents for all the loads at once 2 7 1 Controls a...

Страница 13: ...C 43 0VDC 42 0VDC 2 7 2 Output Voltage Indicator VAC LED illuminated Display indicates output voltage value 2 7 3 Output Current Indicator AMP LED illuminated Display indicates output current value 2...

Страница 14: ...Under Voltage Protection Indicator UVP The under voltage indicator indicates that the power inverter has shut itself down because its input voltage fell below the limits of the inverter see Page12 2 7...

Страница 15: ...on the back of the oven to determine its actual power requirements The AEP 700 inverter will operate small microwave oven 0 2 to 0 3 cubic foot capacity that draws about 780 watts It will provide 3 m...

Страница 16: ...y with a dry cloth to prevent accumulation of dust and dirt At the same time tighten the Screws on the DC input terminals 4 Troubleshooting Guide A common problem with inverter operation is television...

Страница 17: ...nt are the sole remedies and the company shall not be liable for damages whether direct incidental special or consequential caused by negligence or other fault Problem and Symptoms Possible Cause Solu...

Страница 18: ...If battery acid contacts skin or clothing wash immediately with soap and water If acid enters eye immediately flush with running cold water for at least 20minutes and seek medical attention immediate...

Страница 19: ...LTAGE VAC ON 60 OFF OFF 2400 OFF OFF 100 OFF 50 OFF ON 4800 OFF ON 110 ON OFF 9600 ON OFF 115 ON ON 19200 ON ON 120 7 2 220VAC Dip Switch Settings left side of inverter S1 FREQ Hz 50Hz 60Hz S2 S3 BAUD...