Figure 11. Connecting Door Contacts.
Fitting and Wiring Remote Keypads
Figure 9 shows the connector inside of the 625 remote keypad.
Figure 9. Connecting Remote Keypads
1.
Remove the front of the keypad from the back.
2.
Fix the back box to a smooth surface at a convenient height for the user.
3
Connect wiring from the panel to the to the keypad connector.
4.
Wire the second keypad, if fitted, in parallel to the first. Connect the
cable either at the first keypad (daisy chain) or at the panel (star). The
maximum cable length is 100m.
To next keypad
if using daisy
chain wiring
I/P SIG 0 V +V
Normally open
push to make
exit terminate button
Stb Bell 12V 0V TR LS LS OP1 SIG ARM RDY
Note: 625 keypad is supplied
with the 602 panel.
Address
Link
Volume
Control
Sounder
Tamper
Switch
625 Keypad Circuit Board
CONTROL PANEL
Z1
Z2
A/T
A/T
12V
0V
Note: If only one
contact is fitted, wire
it as last contact.
Surface contact
Control panel
14
Installation
496219 Issue 1
601 installation 23/10/1998 10:09 Page 14