Zone Attributes. You can change the way each zone type behaves as follows:
a)
Chime. The panel gives a tone when activated by the detector while un-
set. Chime is only available for Normal Alarms, Entry zones, and
Entry/Exit zones.
b)
Part Set. If the user part sets the panel then it will respond to all zones
programmed as ‘active in part set’.
c)
Omit. The user can isolate any zone programmed as Omit allowed.
Omit is NOT allowed for PA or Entry/Exit zones.
Technical Specification
Zones:
6 Fully programmable closed loop plus global anti-tam-
per.
Display:
LED (on 601).
Keypads:
601 On-board plus two 625 Remote keypads.
602 two remote keypads (one supplied).
Keyswitch:
Full and part set keyswitch option.
Expansion:
None.
Compliance:
Security Standards: BS4737 Pt. 1: (Audibles only).
EMC Standards: Products are tested to EN 50081-1 and
EN 50082-1, and are CE marked accordingly.
Log:
15 events.
Panel Siren:
601 - Yes (80dB at 1m), 602 - not fitted.
Extension Sounder:
1 x 9040 16 Ohm loudspeaker/sounder.
Battery:
1.9 (2.1)Ah Lead acid gel type rechargeable.
12 volt power:
Panel quiescent = 70mA
Keypad quiescent = 40mA.
Aux DC Power:
230mA max at 12 V quiescent.
Dimensions:
h x w x d = 212 x 212 x 68 mm
Weight:
1.2 Kg.
Communicator:
PA + Burg + Open/Close outputs for 660 Speech
Communicator.
Input:
Line fault.
Outputs:
Bell + Strobe (Negative applied (SAB)) giving a total of
500mA at 12V in alarm state. Transistorised OP1: pro-
grammable output for PIR Set Latch, Shock Sensor
Reset, Internal alarm giving 150mA max. Armed and
Ready LED outputs for use with keyswitch set.
Compatible Equipment
625UK-00
Remote keypads (3 wire plus Exit terminate input).
320UK-00
Passive infra red detector.
330UK-00
Passive infra red detector.
660UK-00
4 Channel wire in Speech Communicator.
09040UK-00
16 Ohm loudspeaker.
08506UK-00
“Eurobell” complete with SAB module.