- 35 -
liquid, or expose the battery in an open fire, explosive source or other sources of
danger.
Do not put or store the battery in the environment where the temperature is too high.
Do not put the battery in a microwave oven or a drying machine.
Do not put the battery into a fire.
If the battery leaks, do not let the liquid stain your skin or eyes. Otherwise, wash your
skin or eyes with lots of water and go to see the doctor immediately.
Cleaning MT-6320
Shell
Clean the shell by using a cloth soaked with alcohol, including keys and space between
keys.
Display screen
You can clean the display screen by using a cloth soaked with alcohol. Do not let the liquid
gather around the screen. Otherwise, dry the screen by using a soft non-woven cloth in
case strip marks are left on the screen.
Scan lens
Clean the scan lens regularly by using lens paper or other articles suitable for cleaning
optical materials.
7.2 Troubleshooting
Table 7-1 MT-6320 troubleshooting
Fault
Cause
Solution
After the power key is
pressed, the MT-6320 is
not powered on.
The battery volume is too
low or the battery is not
charged.
Charge the battery or replace the battery.
The battery is incorrectly
installed.
Correctly install the battery.
The system breaks down.
Restore factory settings.
Battery charging fails.
The battery fails.
Replace the battery.
The temperature of the
battery is too high or low.
Put the battery in normal temperature.
During
data
communication, data is
not
transmitted
or
transmitted
data
is
incomplete.
An incorrect data cable is
used.
Contact the system administrator.
The
communication
software
is
incorrectly
installed or configured.
Install or reinstall the ActiveSync software to
update the driver.
The relevant function is
not activated after a user
clicks a button or icon.
The screen is incorrectly
calibrated.
Recalibrate the screen.
The
system
does
not Restart the system.