Scan Combiflex 700 – Manual
Chapter 5
- 30 -
5.6.4 Error codes
Table 5-4
Error codes
Alarm codes starts with “A” and fault codes starts with “F”. The machine will be operational if an alarm
code is present but not when an fault code is present.
The following table describes the access for the task.
Abbreviation Person
O
Machine Operator
E
Electrician
S
Scanmaskin certified service technician
Table 5-5
Access rights for different persons
10
See access table ”Table 5-5”
Code
Description
Cause
Correction
A
10
A2001
Over current
One of the three phases is missing from the
power supply
There is a voltage drop at the power supply
Inspect the fuses in the worksites fuse box
Inspect cables
Measure that all three phases are present and at
full voltage at the cable end near the machine
Make sure that the cable is not to long. If the
cable should be to long, use a cable with higher
rating to a distribution box nearer the machine
O
O
E
E
The environmental temperature is too high.
When the temperature is above 40°C (104°F) the
inverter will decrease its maximum output
current
Inspect the ventilation fans
Inspect the filters to the fans
O
O
A2002
Over voltage
The power supply has got voltage transients
Inspect the power source
E
A2003
Under voltage
One of the three phases is missing from the
power supply
There is a voltage drop at the power supply
See A2001
A2006
Speed reference
error
The potentiometer on the control panel is
damaged
Inspect the potentiometer
Replace if necessary
S
S
A2009
Over
temperature
The internal temperature in the inverter is above
120°C (248°F). This could be caused by faulty
ventilation in the electrical cabinet.
Inspect the ventilation fans
Inspect the filters to the fans
Contact Scanmaskin Sweden AB
O
O
A5001
Internal error
Contact Scanmaskin Sweden AB
F0001
Over current
See A2001
F0002
Over voltage
See A2002
F0003
Over
temperature
The internal temperature in the inverter is above
135°C (275°F). This could be caused by faulty
ventilation in the electrical cabinet.
See A2009
F0004
Short circuit in
motor
The cable to the motor has been damaged
The motor has been damaged
Inspect the motor cable
Inspect the motor connection
Contact Scanmaskin Sweden AB
E
E
F0006
Under voltage
See A2003
F0007
Speed reference
error
See A2006
F0016
Protective earth
failure
The cable to the motor has been damaged
The motor has been damaged
Water have entered the motor
Inspect the motor cable
Inspect the motor connection
Contact Scanmaskin Sweden AB
E
E
F0018
Internal error
Contact Scanmaskin Sweden AB
F0021
F0022
Power supply
phase fault
See A2003
F0034
Motor phase
fault
One of the three phases to the motor is missing.
This could be due to damage to the motor cable
or to the motor.
Inspect the motor cable
Inspect the motor connection
Contact Scanmaskin Sweden AB
E
E
Содержание Scan Combiflex 700
Страница 1: ...SCANMASKIN N Scan Combiflex 700 Users Guide MACHINES MINERALS KNOW HOW http www scanmaskin com...
Страница 6: ...Scan Combiflex 700 Manual v Layout Mountingplate 38 7 Warranty 46 8 EU Declaration 47...
Страница 7: ...Scan Combiflex 700 Manual vi 9 Alphabetical reference 48 10 Contact information 50...
Страница 42: ...Scan Combiflex 700 Manual Chapter 6 36 Grinding head...
Страница 44: ...Scan Combiflex 700 Manual Chapter 6 38 Electrical schematics Layout Mountingplate...
Страница 45: ...Scan Combiflex 700 Manual Chapter 6 39 Layout Panel...
Страница 46: ...Scan Combiflex 700 Manual Chapter 6 40 Connection block...
Страница 47: ...Scan Combiflex 700 Manual Chapter 6 41 Inverter...
Страница 48: ...Scan Combiflex 700 Manual Chapter 6 42 Control Voltage 24 VDC...
Страница 49: ...Scan Combiflex 700 Manual Chapter 6 43 Radio Remote Unit...
Страница 50: ...Scan Combiflex 700 Manual Chapter 6 44 Transport Motor Drivesytem TMD...
Страница 51: ...Scan Combiflex 700 Manual Chapter 6 45 Control Panel...