Fuel system
OPM 320 en-GB
54
©
Scania CV AB 2019, Sweden
3.
Remove the hose spigot and pressure cap
2 655 714 from the charge air pipe.
4.
Open the nipple on pressure cap 2 655 714.
5.
Fit adapter connection 2 655 697 to the pres-
sure regulator and connect it to pressure cap
2 655 714.
6.
Fit the hose spigot and pressure cap
2 655 714 at the throttle housing.
7.
Open the valve on pressure regulator
2 301 851.
8.
Monitor the pressure on pressure testing
equipment 2 284 630. The manometer
should indicate a pressure below 0.3 bar.
Greater pressure may damage the engine.
IMPORTANT!
The pressure must not exceed 0.3 bar. A higher
pressure may damage the turbocharger.
389
3
84
389
3
91
372
3
87