Technical data
|
Installation instructions
|
SCANIA Interlock
®
7x00
31
6 Technical
data
7 Order
list
Measuring principle
Electrochemical DrägerSensor
Measuring range
up to 3.0 mg/L
Ambient conditions
for operation and storage
-40 to 85 °C
20 to 98 % rel. hum.
600 to 1100 hPa
No influence of changes in altitude on the
measurement result
Sensitivity drift
typically 1 % of measured value/month
Display
Display
Calibration interval
typically 12 months
Dimensions (H x W x D)
Handset
approx. 138 mm x 61 mm x 36 mm
Control unit
approx. 148 mm x 90 mm x 32 mm
Weight
Handset
approx. 240 g
Control unit
approx. 240 g
Voltage supply
12 to 24 V
Power consumption
maximum
<2.5 A
stand-by
<1 mA
Switch relay for the lead for the starter relay
continuous
<16 A
peak
<40 A
Output relay
switchable de-energized
48 V
switchable energized
24 V
Ignition lead
5 V to 48 V
Waiting time to be ready for measurement
20 °C
2 s
0°C
<5 s
-25°C
<60 s
-40°C
<110 s
Name and description
Order no.
Mouthpieces (5 pcs.), individually packaged
83 26 550
Mouthpieces (50 pcs.), individually packaged
83 27 627
Mouthpieces (300 pcs.), individually packaged
83 22 597
LTE module
83 27 080
Cable set, LIN/CAN
37 05 279
Cable set for connecting headlights
37 01 238
Cable set for connecting horn
37 01 237
Cable set for connecting external equipment
(AUX/OUT)
37 01 239
Holster for handset
83 22 497
Holster II for handset II
83 22 610
Spiral cord, length 1.5 m
83 15 909