Cooling system
OPM 260 en-GB
50
©
Scania CV AB 2021, Sweden
Draining the sea water circuit
1.
Close the bottom valve on the sea water inlet
and remove the connection pipe (1) on the
outlet from the heat exchanger.
2.
Remove the cover (2) from the sea water
pump to empty the pump completely.
The lowest point in the sea water circuit may be
at different points, but it is usually in the sea wa
-
ter pump intake (3).
IMPORTANT!
Plug the connections to prevent dirt ingress into
the engine.
3
3
0
5
8
6
1
2
3