OPM 260 en-GB
36
©
Scania CV AB 2021, Sweden
Lubrication system
26.
Fit a new O-ring in the cover.
27.
Refit the cover and tighten the lock nut.
Tightening torque 20 Nm (15 lb-ft).
IMPORTANT!
To reduce the risk of oil leakage it is important to
tighten the cover to the correct tightening torque.
Operational testing of the
centrifugal oil cleaner
Operational testing only needs to be performed if
you suspect that the centrifugal oil cleaner is not
functioning as it ought to. This may, for exam
-
ple, be due to abnormally small deposit on the
paper in the centrifugal oil cleaner in relation to
the distance driven.
1.
Run the engine until it reaches normal oper
-
ating temperature.
2.
Turn off the engine and listen for the sound
from the rotor. It should continue rotating for
a time, even when the engine has stopped.
3.
Use your hand to feel if the filter housing is
vibrating.
4.
If the filter housing is not vibrating, disman
-
tle and check the centrifugal oil cleaner.
3
3
3
0
4
3
3
3
3
0
3
9