I N S TA L L AT I O N

Table of contents

Installation ........................................................................ 2

 Installation

 

Approval

 

Technical data and dimensions

Assembly ........................................................................... 3

 

Dimension sketch Scan 

58

 

Unpacking

 Transport 

brackets

 

Service package

 

Accessories

 

Product registration number

 

Type plate

 

Positioning your wood-burning stove

 

Position near to non-flammable walls

 

Distance to furniture

 

Distance to flammable walls

 

Load bearing underlay

 

Floor plate

 

Connection between stove and steel chimney

 

Requirements for chimney

 

Connection with 90° elbow pipe

 

Adjusting screws

 

Fitting the stove onto the plinth

 

Flue collar top outlet

 

Preparing the stove for a rear outlet

 

Fresh air intake

 

Closed combustion system

 

Fitting the soapstone top

 

Fitting a storage door

Instruction for use ........................................................ 12

 

CB Technology

 

Primary air

 

Secondary air

 

Smoke deflector plates

 

Ash pan

 

Handle for riddling grate

Instructions for heating .............................................. 13

 

Lighting

 Handling 

fuels

Maintenance .................................................................. 14

Troubleshooting ............................................................ 16

Installation

The house owner is responsible for ensuring that all necessary nati-
onal and local safety measures are observed during installation and 
fitting and also responsible for observing the fitting and operating 
instructions detailed in this manual.

When you install any kind of fireplace or stove, you must inform the 
local authorities. You are also responsible for calling in a chimney 
sweep to inspect and authorize the installation.

To ensure best-possible functionality and safety for your installa-
tion, we advise you to call a professional fitter. Our  Scan Dealer will 
be able to recommend a qualified fitter in your area. For information 
on Scan Dealers, please go to www.scan.dk.

Approval

If you intend to connect your stove to an existing chimney, it makes 
sense to contact an authorised Scan dealer, or a local chimney sweep 
for advice. These experts will also let you know if your flue needs 
renovating. 

On connecting to a multiple element chimney: follow the vendor‘s 
instructions as applicable to the chimney type (e.g. Leca, Plewa, Ico-
pal, Isokern, Zanda etc.)

No matter whether an authorised Scan dealer installs your stove, or 
you do the job yourself, remember that the chimney sweep has to 
approve the installation before you start to use it.

Technical data and dimensions

CO Emission at 13% O2:                                   0,11%            1338 mg/Nm

3

Dust @ 13% O2:                                                                          44 mg/Nm

3

Nox @ 13% O2:                                                                           119 mg/Nm

Efficiency:                                                                                                  76%

Rated heat load:                                                                                  5,5 kW

Chimney temperature:                                                                      350 °C

Flue outlet flow:                                                                              6,7 g/sec

Recommended vacuum in flue collar:                                               16 Pa

Combustion air requirement:                                                     19 Nm3/h

Recommended fuel:                                                                             Wood

Fuel consumption:                                                                           1,8 Kg/h

Amount of fuel:                                                                                     1,4 kg

Weight:                                                                                                  100 kg

Flue collar internal diameter:                                                         135 mm

Flue collar external diameter:                                                        148 mm

Approval type:                                                           Intermittent fuelling

Intermittent fuelling means normal use of a woodstove. In other 
words, you should let the fire die down until only the embers are 
left, before refuelling.

The Scan 

58

 was build in compliance with the homologized product 

type specified in the Assembly- and Instructions Manual provided 
with the product.

Содержание 58-1

Страница 1: ...ke the best possible use of your stove it is important that you follow our advice and instructions Please read this Assembly and instructions manual before you start to assemble your stove Make a note of your stove s product registration number here so that you have it available if you need to contact us Test in compliance with EN 13240 The EC declaration of conformity is available from www scan d...

Страница 2: ... possible functionality and safety for your installa tion we advise you to call a professional fitter Our Scan Dealer will be able to recommend a qualified fitter in your area For information on Scan Dealers please go to www scan dk Approval If you intend to connect your stove to an existing chimney it makes sense to contact an authorised Scan dealer or a local chimney sweep for advice These exper...

Страница 3: ...inth 1138 500 175 350 1112 294 131 160 Ø 998 Centre rear outlet Height to the beginning of the flue pipe at top outlet Centre of fresh air in take bottom Centre of fresh air intake rear Centre rear outlet Height to the beginning of the flue pipe at top outlet Centre of fresh air in take bottom Service package The service package contains the following Fitting for flue collar Seal Safety fitting Pl...

Страница 4: ... Assembly and instructions for use Product registration number Type plate All Scan wood burning stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materials Scan 58 1 Scan 58 4 without lateral glass panes Scan 58 2 Scan 58 5 with half lateral glass panes Scan 58 3 Scan 58 6 with full lateral glass panes ...

Страница 5: ... product and the wall for cleaning purposes Distance to furniture 1000 mm But please check to avoid furniture or other furnishings being dried out due to being too close to the stove 250 600 45 Corner installation Parallel rear wall installation 250 600 250 350 Scan 58 3 Scan 58 6 with full lateral glass panes Parallel rear wall installation Scan 58 2 Scan 58 5 with half lateral glass panes 45 Cor...

Страница 6: ...and adjust the screws before fitting the stove in place If you are using a shaped floor plate you should adjust the stove upwards to allow the plate to be inserted under the front of the stove Load bearing underlay All of the products in our portfolio are classified as light duty fire places in most cases there is no need to reinforce the floor so that you can typically use the normal floor Howeve...

Страница 7: ...r plate when sweeping the chimney Flue collar Safety fitting B B Bracket Seal for flue collar 4 x Allen screws M6x60 A A Fitting the stove onto the plinth There are two plinths for the Scan 58 You can see how to fit these below Use the key supplied with the service pack to make the atta chment secure A Scan 58 with pedestal plinth If you have decided to connect external combustion air via the pede...

Страница 8: ...d heat shield as follows Drill out the four holes in the cover plates with a Ø6 bit and remove the plates 4 x Allen screws M6x10 C C 3 Undo and remove the blanking plate from the inside This is to be used later as a seal and cover at the top of the smoke outlet 4 Fit the separate flue collar in place from the outside and fix in place using the bracket and seal supplied in the service pack Fit the ...

Страница 9: ...followed with regard to the connection of fresh air intake Closed combustion system If you have decided to use the stove s closed combustion system connect the external combustion air using a ventilation pipe pas sing through the wall or floor It must not be possible to shut off the ventilation pipe with a valve Minimum Ø100 mm ventilation pipe maximum length 6 m with a maximum of one bend The Sca...

Страница 10: ...h the bottom of the plinth unscrew the blanking plate and fit it under the combustion chamber Then fit the connection piece supplied under the plinth as shown below before connecting outdoor air Fitting the soapstone top You can buy a soapstone top for the Scan 58 as an accessory Remove the top plate Refit the four Allen screws and place the soapstone top in position 4 x Allen screws M6x10 E E Rem...

Страница 11: ...3 Fit the rear plate via slots in the stove and holes in the bottom plate F G F G Slot in the stove Holes in the bottom plate Fitting a storage door You can buy a storage door for the Scan 58 with see through plinth as an accessory Fit this as shown below 1 Remove the door 5 x Allen screws M4x10 Magnet for door ...

Страница 12: ...m your wood stove Settings for normal load 50 70 Smoke deflector plates The smoke deflector plates are located in the upper part of the com bustion chamber The plates hold back smoke making sure it stays inside the combustion chamber for a longer time before escaping through the chimney This reduces the smoke gas temperature as the gases have more time to dissipate heat to the wood burning stove T...

Страница 13: ...y is the wood burning stove s motor it s performance decides how well your stove will work The draft in the chimney creates a vacuum in the wood burning stove The vacuum draws the smoke out of the stove and takes in air through the combustion air baffle to fuel the burning process Combustion air is also used for the airwash system that keeps the window clear of soot The draft in the chimney is cau...

Страница 14: ...sy to procure If you use oak or beech wood fuel note that these wood types have a greater fuel value than say birch Make sure you use less fuel to avoid damage to the wood burning stove Combustion chamber lining Slight cracks can appear in the combustion chamber lining due to moisture or to the heating cooling process These cracks have no influence on the heating performance or lifetime of your st...

Страница 15: ...ate in place 2 Lower the smoke deflector plate 3 Turn the smoke deflector plate sideways inside the stove 4 Remove the smoke deflector plate Fitting the combustion chamber sides 1 Remove the lower smoke deflector plate 2 Fit the combustion chamber sides The wide edge should be facing out towards the door when you fit the combustion chamber sides ...

Страница 16: ...roduct registration number when you contact us or your authorised Scan dealer with a warranty claim The warranty covers all parts which in the opinion of Scan A S require repair or replacement due to manufacturing or construction error The warranty applies to the original purchaser of the product only and is not transferable except on prior sale The warranty covers only damage caused by manufactur...

Отзывы: