Scales USA ACS001AC Скачать руководство пользователя страница 6

SCALES usa © 2005

Page

6 of 16

SETUP

GENERAL INSTALLATION

The scale should be sited in a location that will not degrade the 
accuracy.

Avoid extremes of temperature. Do not place in direct sunlight or near 
air conditioning vents.

Avoid unsuitable tables. The tables or floor must be rigid and not 
vibrate. Do not place near vibrating machinery.

Avoid unstable power sources. Do not place near large users of 
electricity such as welding equipment or large motors.

Avoid high humidity that might cause condensation. Avoid direct 
contact with water. Do not spray or immerse the scale in water.

Avoid air movement such as from fans or opening doors. Do not place 
near open windows.

Keep the scale clean.

Do not stack material on the scale when not in use.

INSTALLATION OF ACS A/C SERIES

Level the scale using adjustable feet. Center the bubble in the spirit 
level located on the left of the scale control panel.  If the scale rocks 
readjust the levelers.

The ACS A/C Series comes with a stainless steel platform packed 
separately. Place the platform in the locating holes on the top of the 
scale. Do not press with excessive force as this could damage the load 
cell inside.  There is a protective peel-off plastic coating on the platform 
and on the display that may be removed if desired.

For AC operation or charging of internal battery, set the power source 
selection switch on the lower left side of the scale to the battery 
position and attach the power supply cable to the connector on the 
bottom of the scale.  Be certain that it is firmly seated and that the 
shoulder of the plug fits into the hole in the scale case. Plug in the 
power supply module. The power switch is located on the bottom right 
side of the scale.  See Figure 2.

FOR Dry Cell operation, set the power source selection switch on the 
lower left side of the scale to Dry Cell.  Insert 4 

C SIZE

 alkaline 

batteries.  Do not store the scale with batteries installed if it will not be 
used for over 30 days to precent damage from battery corrosion.

The battery charge light will illuminate whenever the scale is attached 
to power.

Содержание ACS001AC

Страница 1: ...SCALES usa 2005 Page 1 of 16 ACS Series Digital Counting Scales USER MANUAL...

Страница 2: ...SCALES usa 2005 Page 2 of 16...

Страница 3: ...cities up to 60lb 30 kg They all have stainless steel weighing platforms on an ABS base assembly All the keypads are sealed membrane switches and the displays are large easy to read liquid crystal typ...

Страница 4: ...e 1 7 2 KEYBOARD 8 Figure 2 8 SCALE OPERATION 9 Power on 9 Figure 3 9 Figure 4 9 ZEROING THE DISPLAY 10 TARING 10 NORMAL TARE 10 PRETARE 11 PARTS COUNTING 11 SETTING UNIT WEIGHT 11 WEIGHING A SAMPLE T...

Страница 5: ...of Measure kg g lb oz kg g lb oz kg g lb oz kg g lb oz kg g lb oz Recommended Calibrationtion Weight 1KG 2KG or 3KG 5KG 10KG 20KG Common Specifications Interface RS 232 Output NA Stabilization Time 2...

Страница 6: ...s The ACS A C Series comes with a stainless steel platform packed separately Place the platform in the locating holes on the top of the scale Do not press with excessive force as this could damage the...

Страница 7: ...ed STABLE The symbol appears when the reading is stable LOS The Lack of Sample symbol appears when the sample number on the platform is not enough for accurate counting operation LPW The Lack of Piece...

Страница 8: ...ls the total accumulated weight and count from the memory UNIT WEIGHT CANCEL Used to enter the known unit weight In the setup mode this key is used as a cancel and exit key SAMPLE BACK LIGHT Used to i...

Страница 9: ...an be used as shift key CE Used to clear the displayed numeric readings SCALE OPERATION Power on Place the scale horizontally by adjust four leveling feet at the bottom of the scale to place the bubbl...

Страница 10: ...key at any time to set the zero point from which all other weighing and counting is measured It is active within 4 of power up zero This will usually only be necessary when the platform is empty When...

Страница 11: ...value for the Pretare weight IN GRAMS including decimal values 50 00 Using the keypad press Tare to store the tare value The weight will show a negative value equal to the tare Note If you have the sc...

Страница 12: ...ossible to enter that value using the keypad When weighing in kilograms or grams the unit weight is entered in grams When weighing in pounds the unit weight is entered in pounds When weighing in ounce...

Страница 13: ...3 To observe the total stored press the TOTAL key 4 To clear the memory press TOTAL and then QUANTITY CHECK to clear all values from memory BATTERY OPERATION The scales can be operated from the intern...

Страница 14: ...bility is but the slower the reaction is For example SEL 1 0 means the reaction of the scale is the quickest but its stability is the lowest SEL2 3 means the reaction of the scale is the lowest but it...

Страница 15: ...he UnIt menu to enter it choose the desired unit by Shift key ZERO Press M to save it The display will show next menu Or press the UNIT WEIGHT CANCEL key to exit BK lg SELECTION OF BACKLIGHT MODE Ther...

Страница 16: ...not arising out of defects in materials or workmanship During the one year warranty period if your scale fails to work properly when used under normal conditions Scales USA will repair or at our optio...

Отзывы: