Scales USA ACS001AC Скачать руководство пользователя страница 10

SCALES usa © 2005

Page

10 of 16

For AC operation or charging of internal battery, set the power source 
selection switch on the lower left side of the scale to the battery 
position and attach the power supply cable to the connector on the 
bottom of the scale.  Be certain that it is firmly seated and that the 
shoulder of the plug fits into the hole in the scale case. Plug in the 
power supply module. The power switch is located on the bottom right 
side of the scale.

FOR Dry Cell operation, set the power source selection switch on the 
lower left side of the scale to Dry Cell.  Insert 4 

C SIZE

 alkaline 

batteries.  Do not store the scale with batteries installed if it will not be 
used for over 30 days to prevent damage from battery corrosion.

Turn on the power switch at the bottom of the scale (See Figure 4). 
The display will show 0

9 sequentially and battery voltage value (over 

5.5v) for several seconds. Then it will enter the weighing mode.  The 
weight will display zero and the zero sign

“”

appears

.

ZEROING THE DISPLAY

You can press the 

ZERO 

key at any time to set the zero point from which all 

other weighing and counting is measured, It is active within 4% of power up 
zero. This will usually only be necessary when the platform is empty. When 
the zero point is reached, the Weight display will show the indicator for zero.
The scale has an automatic re-zeroing function to account for minor drifting or
accumulation of material on the platform. However you may need to press 

ZERO 

to re-zero the scale if small amounts of weight are shown when the 

platform is empty.

TARING

The Tare function is used to remove the package weight, effectively setting 
the weight display to zero.  If the item tarred is removed, a negative weight is 
displayed.  This allows weighing or counting only the contents of the 
container. 
There are two methods to enter a tare value. Normal Tare uses the weight on 
the platform and Pretare uses a value input by the user.

NORMAL TARE:

Zero the scale by pressing the 

ZERO 

key if necessary. The zero 

indicator will be on.

Place a container on the platform, a value for its weight will be 
displayed.

Press the 

TARE 

key to tare the scale. The weight that was displayed is 

stored as the tare value and that value is subtracted from the display, 
leaving zero on the display.

Содержание ACS001AC

Страница 1: ...SCALES usa 2005 Page 1 of 16 ACS Series Digital Counting Scales USER MANUAL...

Страница 2: ...SCALES usa 2005 Page 2 of 16...

Страница 3: ...cities up to 60lb 30 kg They all have stainless steel weighing platforms on an ABS base assembly All the keypads are sealed membrane switches and the displays are large easy to read liquid crystal typ...

Страница 4: ...e 1 7 2 KEYBOARD 8 Figure 2 8 SCALE OPERATION 9 Power on 9 Figure 3 9 Figure 4 9 ZEROING THE DISPLAY 10 TARING 10 NORMAL TARE 10 PRETARE 11 PARTS COUNTING 11 SETTING UNIT WEIGHT 11 WEIGHING A SAMPLE T...

Страница 5: ...of Measure kg g lb oz kg g lb oz kg g lb oz kg g lb oz kg g lb oz Recommended Calibrationtion Weight 1KG 2KG or 3KG 5KG 10KG 20KG Common Specifications Interface RS 232 Output NA Stabilization Time 2...

Страница 6: ...s The ACS A C Series comes with a stainless steel platform packed separately Place the platform in the locating holes on the top of the scale Do not press with excessive force as this could damage the...

Страница 7: ...ed STABLE The symbol appears when the reading is stable LOS The Lack of Sample symbol appears when the sample number on the platform is not enough for accurate counting operation LPW The Lack of Piece...

Страница 8: ...ls the total accumulated weight and count from the memory UNIT WEIGHT CANCEL Used to enter the known unit weight In the setup mode this key is used as a cancel and exit key SAMPLE BACK LIGHT Used to i...

Страница 9: ...an be used as shift key CE Used to clear the displayed numeric readings SCALE OPERATION Power on Place the scale horizontally by adjust four leveling feet at the bottom of the scale to place the bubbl...

Страница 10: ...key at any time to set the zero point from which all other weighing and counting is measured It is active within 4 of power up zero This will usually only be necessary when the platform is empty When...

Страница 11: ...value for the Pretare weight IN GRAMS including decimal values 50 00 Using the keypad press Tare to store the tare value The weight will show a negative value equal to the tare Note If you have the sc...

Страница 12: ...ossible to enter that value using the keypad When weighing in kilograms or grams the unit weight is entered in grams When weighing in pounds the unit weight is entered in pounds When weighing in ounce...

Страница 13: ...3 To observe the total stored press the TOTAL key 4 To clear the memory press TOTAL and then QUANTITY CHECK to clear all values from memory BATTERY OPERATION The scales can be operated from the intern...

Страница 14: ...bility is but the slower the reaction is For example SEL 1 0 means the reaction of the scale is the quickest but its stability is the lowest SEL2 3 means the reaction of the scale is the lowest but it...

Страница 15: ...he UnIt menu to enter it choose the desired unit by Shift key ZERO Press M to save it The display will show next menu Or press the UNIT WEIGHT CANCEL key to exit BK lg SELECTION OF BACKLIGHT MODE Ther...

Страница 16: ...not arising out of defects in materials or workmanship During the one year warranty period if your scale fails to work properly when used under normal conditions Scales USA will repair or at our optio...

Отзывы: