STEP 3:  AT THE FIREPLACE 

A. Mount bracket in fireplace 

• 

Using 1/4” masonry drill bit, drill one hole about 1” deep into firebrick towards 

 the front of the fireplace and about 20” off the firebox floor (see illustration).

 

Important: If brick is loose, first repair it with refractory 
mortar or call local mason. 

Caution: Wear safety glasses when drilling. Use only 
masonry drill bit. Failure to do so can cause cracks in the 
firebox wall.  

 

• 

Insert nail anchor in top hole of bracket and secure 

to firebox wall with hammer. 
• 

Drill second hole after bracket is attached to 

firebox wall. Add second nail anchor and secure. 

[Illustration Call Outs: Placement of Bracket in 
Firebox] 

 

B. Install cable handle 

• 

Pull cable through bracket until a slight tension 

can be felt. Damper should now be closed. 
• 

Slide brass lug onto cable 1/2” above bracket (see 

illustration). 
• 

Close damper by pulling cable down and placing 

lug under bracket. 

[Illustration Call Outs: Cable, Lug, Bracket, Handle, 
Bracket and Handle Assembly] 

 

C. Check and adjust operation 

• 

Return to the roof and check that the damper is tightly sealed. If it is not, adjust lug 
upward for better seal. Do not overdo it – if lug is raised too far, this may activate the 
cable leg and actually open the damper. 

• 

Cut off excess cable. 