Navsight Solution
– Hardware Manual
NAVSIGHTHM.1.5
5.12. Internal Datalogger
Navsight includes an internal data-logger capable of storing all data at 200 Hz for 48 hours. The internal
data-logger is composed of a high speed memory buffer and an 8 GB flash storage.
Access to the logged data is ensured by accessing the FTP server.
5.13. Power supply interface
The power supply uses a 2 ways male Push-pull ODU connector reference G81F1C-P02MPH00000. The
connector mates with the following plug reference: S31F1C-P02LPN0-350S. It is also compatible with other
manufacturers such as Fischer Core Series.
Both Rugged processing unit and rack processing unit use the same power connector.
Note: Power connector share the same specifications & pin-out as Ekinox, Apogee surface units, as
well as Splitbox units. However, previously provided power supplies may not provide sufficient
current outputs for Navsight operation.
5.13.1. Connector pin-out
Pin #
Name
Description
SHIELD
SHIELD
Connected to mechanical ground
1
VIN+
Power supply input
2
VIN-
Power supply return
47/73
Figure 5.18: Power plug top view
Figure 5.17: Power receptacle front view