Navsight Solution
– Hardware Manual
NAVSIGHTHM.1.5
The default center of measurement is located on top of Horizon enclosure, on the coordinate frame center
drawing. It is represented on the mechanical outlines by the symbol. This point is defined to simplify
installation.
Alternatively, user can select between two other center of measurement points:
●
Alignment hole (aligned to the bottom of the base plate)
●
Bare IMU center of measurement, represented by the symbol.
2.2.4. Specifications
The table below summarizes all mechanical and environmental specifications.
Electrical and Mechanical Specifications
Enclosure materials
Anodized Aluminum (6061)
Dimensions
15 x 16.8 x 21.5 cm
Weight
4.29 kg
Input power voltage
18 – 32 VDC
Power consumption
12 W typical
Environmental specifications
Altitude rating
55 000 feet
IP rating
IP-67
Humidity
Sealed, no limit
Operating Temperature
range
-20°C to 60°C – specified range
-40°C to 71°C – operating range
Storage Temperature range
-40°C to 71°C
Shocks
6.0 g; 20 ms half-sine (operational)
40 g; 15 ms half-sine (non operational)
Operating Vibrations
4.1 g RMS – DO-160F, Cat. SC
Calibration interval
None required, maintenance free
17/73