Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 

satisfactory operation of this product. Please retain these instructions for future reference.

Warning

Specification 

Supply: 

240V ~ 50Hz

Lamp: 

4.5W LED

IP rating: 

65

Layout

This product is suitable for use in 

Zone 1 and  Zone 2 and outside Zones 
in a bathroom. See diagram.
If this unit is being fitted in a room 
containing a bath or shower, a 30mA 

RCD must be used - in accordance 

with IEE regulations.

•  These are only suitable for fitting to a plasterboard 

fire rated ceiling.

•  Plan the desired layout of these fittings carefully, 

ensuring the cables will reach the distances between 
the transformer and each light fitting.

•  Ensure that there is adequate ventilation for the LED 

driver.

•  Avoid locating any cables in positions that would 

cause a hazard. Position cables and junction boxes 

(not supplied) away from areas where they may be 
at risk from being cut, trapped or damaged

•  The mains supply cable must have a minimum cross 

sectional area of 1.0mm²

•  The distance between units must be 0.5m minimum.

•  The unit must be located 0.2m away from a joist.

•  This product must be mounted out of arms reach.

•  This product is rated at IP65.

Ensure free movement of air around the fitting by removing any roof void insulation from at least 
150mm around the hole. Under no circumstances must these fittings and drivers be covered with 
insulating matting or similar material.

Ceiling Preparation

Existing fittings must be completely removed before 
installation of a new product. Before removing the 
existing fitting, 

carefully note the position of each set 

of wires

.

•  Position the LED driver next to the mains outlet that 

the system will connect to. Do not connect at this 

stage.

•  After deciding the layout of the light fittings ensure 

that the cables are long enough to connect to the 

desired positions.

•  Ensure a minimum ceiling void depth of 90mm is 

available.

•  Cut a mounting hole 57mm diameter in the ceiling 

taking care not to foul any pipes, mains cables or 
joists beneath the surface.

•  It is always recommended to cut the hole slightly 

smaller than the size specified, and then file the hole 
until the recessed unit fits snugly.

This product is Double Insulated and does 
not require connection to an Earth circuit.

Please read these instructions carefully before 
commencing any work.

This unit must be fitted by a competent and qualified 

electrician.

Install in accordance with IEE Wiring regulations and 

current Building Regulations.

This system operates at Safety Extra Low Voltage, via 
the supplied LED driver. Never connect the light fittings 
directly to the mains without using the supplied LED 

driver.

To prevent electrocution switch off at mains supply 

before installing or maintaining this fitting. Ensure 
other persons cannot  restore the electrical supply 
without your knowledge.

This light fitting must be connected to a fused circuit.

If replacing an existing fitting, make a careful note of 
the connections.

These fittings are only suitable for fitting to a 
plasterboard fire rated ceiling. This fitting must always 
be fitted to a plasterboard ceiling. This must not be 

fitted to a plaster and lath ceiling. 

This system contains non-replaceable parts and 

cannot be serviced. If damage occurs the part should 
be scrapped.

Waste electrical products should not be disposed of 
with household waste. Please recycle where facilities 
exist. Check with your local authority or retailer for 
recycling advice.

                       This product is NOT suitable for  

 

       direct mounting on normally 

flammable surfaces (suitable only for mounting on 

non-combustible surfaces).  

                        

Wiring

The LED Driver is double insulated and must not be earthed. If there are any incoming earth cables, they must be 
joined together and well insulated with good quality insulation tape. This is to ensure earth continuity throughout your 

property. 

Remove the cover from the mains terminals and having correctly identified the wiring from your existing light fitting, 
pull the mains wiring through the hole and connect to the connection block inside the LED driver.

Either the outside or inside terminals can be used, including loop through connections.

Mains Live (L - Brown)

Mains Neutral (N - Blue)

L

N