Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
Specification
Supply:
240V ~ 50Hz
Lamp:
4.5W LED
IP rating:
65
Layout
This product is suitable for use in
Zone 1 and Zone 2 and outside Zones
in a bathroom. See diagram.
If this unit is being fitted in a room
containing a bath or shower, a 30mA
RCD must be used - in accordance
with IEE regulations.
• These are only suitable for fitting to a plasterboard
fire rated ceiling.
• Plan the desired layout of these fittings carefully,
ensuring the cables will reach the distances between
the transformer and each light fitting.
• Ensure that there is adequate ventilation for the LED
driver.
• Avoid locating any cables in positions that would
cause a hazard. Position cables and junction boxes
(not supplied) away from areas where they may be
at risk from being cut, trapped or damaged
• The mains supply cable must have a minimum cross
sectional area of 1.0mm²
• The distance between units must be 0.5m minimum.
• The unit must be located 0.2m away from a joist.
• This product must be mounted out of arms reach.
• This product is rated at IP65.
Ensure free movement of air around the fitting by removing any roof void insulation from at least
150mm around the hole. Under no circumstances must these fittings and drivers be covered with
insulating matting or similar material.
Ceiling Preparation
Existing fittings must be completely removed before
installation of a new product. Before removing the
existing fitting,
carefully note the position of each set
of wires
.
• Position the LED driver next to the mains outlet that
the system will connect to. Do not connect at this
stage.
• After deciding the layout of the light fittings ensure
that the cables are long enough to connect to the
desired positions.
• Ensure a minimum ceiling void depth of 90mm is
available.
• Cut a mounting hole 57mm diameter in the ceiling
taking care not to foul any pipes, mains cables or
joists beneath the surface.
• It is always recommended to cut the hole slightly
smaller than the size specified, and then file the hole
until the recessed unit fits snugly.
This product is Double Insulated and does
not require connection to an Earth circuit.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
This system operates at Safety Extra Low Voltage, via
the supplied LED driver. Never connect the light fittings
directly to the mains without using the supplied LED
driver.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge.
This light fitting must be connected to a fused circuit.
If replacing an existing fitting, make a careful note of
the connections.
These fittings are only suitable for fitting to a
plasterboard fire rated ceiling. This fitting must always
be fitted to a plasterboard ceiling. This must not be
fitted to a plaster and lath ceiling.
This system contains non-replaceable parts and
cannot be serviced. If damage occurs the part should
be scrapped.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
This product is NOT suitable for
direct mounting on normally
flammable surfaces (suitable only for mounting on
non-combustible surfaces).
Wiring
The LED Driver is double insulated and must not be earthed. If there are any incoming earth cables, they must be
joined together and well insulated with good quality insulation tape. This is to ensure earth continuity throughout your
property.
Remove the cover from the mains terminals and having correctly identified the wiring from your existing light fitting,
pull the mains wiring through the hole and connect to the connection block inside the LED driver.
Either the outside or inside terminals can be used, including loop through connections.
Mains Live (L - Brown)
Mains Neutral (N - Blue)
L
N