ENGLISH
18
TROUBLESHOOTING
Temperature sensor 1
not connected.
Temperature sensor 1
short circuit.
Temperature sensor 2
not connected.
Temperature sensor 2
short circuit.
Temperature fuse defect.
E1
E2
E3
E4
E5
Check the wire between the sensor and the
control unit.
If there is no problem with the wires and they
are correctly installed, check the sensor.
If no problem can be found, contact the retailer.
Check the wire between the fuse and the control
unit. Fuse has probably overheated. The reason
for it needs to be discovered before using the
steam generator again. A new fuse is needed.
If no problem can be found, contact the retailer.
Code
Problem
Solution
If an error occurs the steam generator will automatically
switch off. A warning beep will alarm the user every 2
seconds. The error code will be displayed blinking in
the control panel, see the table below.
Please note, only a qualified electrician or maintenance
personnel are allowed to make service operations and
repairs! Long press OK button to switch OFF Mode.
For Tandem Connection:
If an error occurs in one of the slave units, error message
is followed by slave number. For example: E1 -> S2
-> E1 ->S2... Pressing the ON/OFF button disables the
slave and rest of the generators can operate normally.
See steam generator manual for tandem connection.
Error codes: