Sawo STAINLESS STEEL TOUCH CONTROL Скачать руководство пользователя страница 1

MANUAL

ENGLISH

STAINLESS STEEL TOUCH CONTROL

FOR STP and STN STEAM GENERATORS

Congratulations on your purchase of Stainless Steel Touch Control Unit!

Please read the manual carefully before using the steam generator.

Not for use in the USA, Canada and Mexico.

Содержание STAINLESS STEEL TOUCH CONTROL

Страница 1: ...EEL TOUCH CONTROL FOR STP and STN STEAM GENERATORS Congratulations on your purchase of Stainless Steel Touch Control Unit Please read the manual carefully before using the steam generator Not for use in the USA Canada and Mexico ...

Страница 2: ...DE 10 Steam ON 10 Day and Session Time 10 Temperature Setup 10 Optional features 11 Aroma 11 Dimmer 11 Fan 11 STANDBY MODE 12 Current Day and Standby Time 12 Pause Button 12 DRAIN MODE 12 EASY MODE 13 Hidden Button 13 Steam ON 13 STEAM GENERATOR DIP SWITCHES 14 Standby Time 14 Session Time 14 First Block of 8 Switches 14 DIP Switches for Naming Slaves 14 SIP Swittches for Other Functions 14 CONTRO...

Страница 3: ... steam However if the steam room is not used constantly the generator can be set to Standby Mode During the Standby Mode water and steam room are kept warm with minimal energy consumption The generator is able to produce steam shortly after the unit is switched back to ON mode for the user s convenience INDICATORS Light ON Animated Dimmer optional feature Fan ON Animated optional feature Aroma ON ...

Страница 4: ...n main power supply of the generator must be switch off from the circuit breaker Mount the control unit in the wall according to the specifications given below Follow the illustrations NOTE Run the Factory Reset after installing the steam generator for the first time or after changing the control panel See page 8 152 mm 77 mm Locks 1 2 Metal Casing Control Panel Cut 1 3 2 4 Snap in the control pan...

Страница 5: ... the display to turn it on Current day Time Button Day and Clock button is displayed in the OFF Mode It shows the current day and time Long press the button to jump into Pre Set Time setup See page 9 Pre set time setting Light Button Toggle the light button to switch ON OFF your steam room lights When your steam generator has a dimmer feature you can adjust the brightness from 0 100 Dimmer setting...

Страница 6: ...t or long pressing the buttons Long pressing hour or minute button will change numbers faster Kilowatt Value Set the correct kilowatt value of the steam generator to the control see kilowatt information on your steam generator Press the arrow up or down to select Counters Counters display the usage of time and kilowatt of the steam generator This information is very necessary to evaluate the need ...

Страница 7: ...n on how to decalcify your steam generator tank See page 17 Blackout Memory Active Blackout Memory restores control to its previous statebeforepowerfailure Forexample ifsteamgenerator was on before power failure the steam generator will automatically continue from the previous state Temperature Scale You may set the temperature scale either Celsius or Fahrenheit Standby Temperature Settings Steam ...

Страница 8: ... Contrast Setting You can adjust the contrast of the display between 0 and 100 Factory Reset Press the HeE RESET to remove heating element error after checking or fixing the heating elements If steam generator s kW is changed press reset button instead Pressing the RESET button will revert all settings to factory default This is used when there is a malfunction on the machine or you wish to clear ...

Страница 9: ...an set the day and time for your steam session Darkened area is the active area that can be modified Press arrows left or right to change settings Tap the active area to jump into next setting When start time and end time are same there is no steam session Maximum session time depends on the dip switch setting on the steam generator See Steam Generator DIP switches at page 14 Three arrow button co...

Страница 10: ...icates current day which can be set in the Day and Time setup in Settings Menu Session time is the remaining time of using the steam room The session time can be set until 24hours and it counts down When Day and Session button is pressed a setup screen will appear Use arrows up and down to change the session time and hit OK when values are set Maximum length of the session time can be set on the D...

Страница 11: ...19 This function operates only in ON mode In case if aroma setting is switched off or the Session Time expires on the next steam session previous settings apply Dimmer When your steam generator has a dimmer feature you can adjust the light brightness from 0 100 Dimmer setting appears when you turn on the light or long press the light button while light is on Fan Short press the fan button to turn ...

Страница 12: ...ndby time is set by dip switches in the steam generator Refer to page 14 Pause Button Short press the pause button to switch to On Mode Long press it to switch to Off Mode If autodrain is present long press pause button to switch to Drain Mode DRAIN MODE Only applicable when autodrain is enabled by the Steam Generator DIP switches refer to page 12 and in the Settings Menu refer 3 5 4 The autodrain...

Страница 13: ...re and lights buttons to change their settings Hidden Button Press the hidden button for 10 seconds to switch to Off Mode Hidden button is active in Off and in Easy Mode Steam ON Animated Steam ON button indicates that steam generation is ongoing Short pressing this button will switch off the steam generator If autodrain is on long press of the Steam ON button activates the Drain Mode If autodrain...

Страница 14: ...resent Not Present Not Connected No Fan Scent Pump Auto Drain Temperature range Slave Unit Slave Number Slave Number DIMMER FAN SCENT PUMP DRAIN TEMP SLAVE STANDBY SESSION 1 ON OFF 0 STAND BY ON OFF DIP No Function 8 Standby mode duration 7 6 5 4 3 2 1 Standby mode duration Standby mode duration Maximum session time Maximum session time Maximum session time Maximum session time Disable standby mod...

Страница 15: ...isplay Set temperature will be shown in display 4 Start up logo Start up logo Start up logo Easy mode UI is set to Easymode Normal mode cannot be activated by user Start default in normal mode Easy mode can be activated by user 3 2 1 No Logo 0 0 1 Sawo Logo 0 0 0 Function On 1 Off 0 Default TEMPERATURE EASY MODE 1 ON OFF 0 START UP LOGO DIP ON 1 2 3 4 5 6 7 8 ...

Страница 16: ...tial free momentary or latching contacts Long press OK button if alarm has been settled Remote On Used for automated households The remote signal is a potential free contact The steam generator switches on when contact is closed and remains on until contact is opened When the steam generator is remotely controlled settings used from previous session are applied Other buttons are locked Only the Li...

Страница 17: ...n into the tank Return back the cap to its original position when done After pouring the solution press OK on the screen Steam generator will automatically go through decalcifying process including draining After process is done screen will go to off state Fill and drain the tank with water two times more by switching ON and draining the steam generator 1 2 3 4 Steam Generator kW 3 7 5 9 15 Decalc...

Страница 18: ...ator again A new fuse is needed If no problem can be found contact the retailer Code Problem Solution If an error occurs the steam generator will automatically switch off A warning beep will alarm the user every 2 seconds The error code will be displayed blinking in the control panel see the table below Please note only a qualified electrician or maintenance personnel are allowed to make service o...

Страница 19: ...nnected and not blocked Clean the level probes If no problem can be found contact the retailer Check the RJ12 cable If the area where cable is located has many other cables it can cause EMC problems If no problem can be found contact the retailer Contact qualified electrician or maintenance personnel before using the steam generator again Dip switch setting is incorrect Check dip switch settings C...

Страница 20: ...www sawo com info sawo com Subject to change without notice STN_SST_ML_ En0119 ...