【How to Replace Cooling Unit】
1. Remove the door (Fig.1)
Open the door and take out the basket.
Remove four screws which hold hinges. (Fig.1-①)
2. Remove the motor cover. (Fig.2)
Remove two screws of motor cover. (Fig.2-①)
Remove two screws of case cover assy. (Fig.2-②)
3. Take out the power supply. (Fig.3)
Cut the fastener. (Fig.3-①)
Remove two screws of power supply. (Fig.3-②)
Pull out four couplers. (Fig.3-③)
Pull out coupler. (LED LIGHT; MT35F / 45F-TH, G4-S Only) (Fig.3-④)
Take out the power supply. (Fig.3-⑤)
7. REPLACING PARTS
13
Fig.2
Fig.3
②
①
①
③
DOOR
Fig.1
14mm
14mm
WORK TIPS
When re-installing for door and hinges, please be care with placing position
of hinge height. Position must be 14mm from the cabinet.
(Please see reference picture in below)
After installation of door, please make sure for interior light not leak from
side of door.
If it's possible to see the light, please adjust height of hinges.
MOTOR COVER
CASE COVER ASSY
⑤
②
③
①
POWER SUPPLY
GROUND CORD
④
Содержание 0642 032 0R12
Страница 7: ... MT35F MT45F 3 PART NAME 4 ...
Страница 8: ... Block Diagram MODEL MT35F U1 MT45F U1 Wiring Diagram MODEL MT35F U1 MT45F U1 5 4 CONNECTING DIAGRAM ...