【Check 1】 Special Fuse & Blade Fuse. (Fig.1)
◇ Check the resistance of special fuse by tester.
Test result
Judge
0Ω
Normal
∞Ω
Broken
◇ Check the blade fuse. (G3, G4 Type only)
The blade fuse is in the power supply.
To remove the blade fuse, please remove the power supply.
【Check 2】 Output Voltage of the Power Supply.
(Fig.2)
◇ Checking point
Check at two pin coupler of power supply. (Fig.2)
Test result
Judge
Approx. AC13 - 17V
Normal
AC 0 V
Power Supply is broken
Approx. AC13V or lower
Compressor is locked
【Check 3】 Check the Resistance at the Coil if Compressor.(Fig.3)
◇ Checking points
Remove two pin coupler at motor cord, and check.
Test result
Judge
Approx. 1.69 Ω
Normal
∞Ω
Broken
0Ω
Coil of compressor is short circuit
6. CHECK POINT
&
CHECK METHOD
10
・Please attach attention to the special fuse of
orientation.
・It can not detect the temperature is in the wrong
special fuse orientation. (※)
Fig.1
Fig.2
DC CORD
Fig.3
POWER SUPPLY
POWER SUPPLY
SPECIAL FUSE