background image

2

3. SAFETY RULES

1.  To reduce the risk of electric shock, insure 

electricity has been turned off at the 
circuit breaker or fuse box before 
beginning.

2.   All wiring must be in accordance with the 

National Electrical Code and local 
electrical codes. Electrical installation 
should be performed by a qualified 
licensed electrician.

3. 

WARNING:

 To reduce the risk of electrical 

shock and fire, do not use this fan with 
any solid-state fan speed control device.

4. 

WARNING:

 To reduce the risk of personal 

injury, use only the two steel screws (and 
lock washers) provided with the outlet 
box for mounting to the outlet box. Most 
outlet boxes commonly used for the 
support of lighting fixtures are not 
acceptable for fan support and may need 
to be replaced, consult a qualified 
electrician if in doubt.

5.  The outlet box and support structure must 

be securely mounted and capable of 
reliably supporting a minimum of 50 
pounds. Use only ETL Listed outlet boxes 
marked

 "FOR FAN SUPPORT".

6.  The fan must be mounted with a minimum 

of 7 feet clearance from the trailing edge 
of the blades to the floor.

7.   Do not operate reversing switch while fan 

blades are in motion. Fan must be turned 
off and blades stopped before reversing 
blade  direction.

8.   Avoid placing objects in the path of the 

blades.

9.   To avoid personal injury or damage to the 

fan and other items, be cautious when 
working around or cleaning the fan.

10.  Do not use water or detergents when 

cleaning the fan or fan blades.  A dry dust 
cloth or lightly dampened cloth will be 
suitable for most cleaning.

11. After marking electrical connections, 

spliced conductors should be turned 
upward and pushed carefully up into 
outlet box. The wires should be spread 
apart with the grounded conductor and 
the equipment-grounding conductor on 
one side of the outlet box.

12.  Electrical diagrams are reference only. 

Light kit that are not packed with the fan 
must be ETL Listed and marked suitable 
for use with the model fan you are 
installing. Switches must be ETL General 
Use Switches. Refer to the Instructions 
packaged with the light kits and switches 
for proper assembly.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK OR PERSONAL INJURY, MOUNT FAN 

TO OUTLET BOX MARKED 

"ACCEPTABLE 

FOR FAN SUPPORT".

WARNING

TO REDUCE THE RISK OF PERSONAL INJURY, 

DO NOT BEND THE BLADE BRACKETS (ALSO 

REFERRED TO AS FLANGES) DURING 

ASSEMBLY OR AFTER INSTALLATION. DO NOT 

INSERT OBJECTS IN THE PATH OF THE BLADES.

Содержание 60-5025-313-13

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V 60Hz UL LISTED MODEL LP8146 FN666 MODEL 60 5025 313 13 60 5025 3SV SN 60 5025 3KO SN CEILING FAN OWNER S MANUAL ...

Страница 2: ...r h Transmitter holder 2 mounting screws 3 volt battery CR2032 i Package hardware 1 Mounting hardware screws 2 lock washers 2 star washers 2 wire nuts 3 wood screws 2 washers 2 2 Blade attachment hardware screws 7 washers 7 lock washers 7 3 Safety cable hardware wood screw 1 lock washer 1 metal washer 1 1 Philips screw driver Blade screw driver 11 mm wrench Step ladder Wire cutters 1 TOOLS AND MAT...

Страница 3: ...switch while fan blades are in motion Fan must be turned off and blades stopped before reversing blade direction 8 Avoid placing objects in the path of the blades 9 To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan 10 Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be ...

Страница 4: ...materials The outlet box and its support must be able to fully support the moving weight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 Outlet box Provide strong support Recessed outlet box Ceiling...

Страница 5: ...Route wires exiting from the top of the fan motor through the collar cover canopy cover canopy and then through the ball downrod Fig 7 Step 7 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Fig 7 Carefully insert the hanger pin through the holes in the collar and downrod Be careful not to jam the pin against the wiring inside the downrod Insert...

Страница 6: ...he WHITE wire Neutral from the outlet box to the WHITE wire marked AC in N from the motor Fig 10 Step 2 Connect the BLACK wire Hot from the outlet box to the BLACK wire marked AC in L from the motor Fig 10 Step 3 Figure 10 If your outlet box has a ground wire green or bare copper connect it to the fan ground wires otherwise connect the hanging bracket ground wire to the mounting bracket Secure the...

Страница 7: ... canopy screws as necessary until the canopy and canopy cover are snug Fig 11 Warning Make sure tab at bottom of hanger bracket is properly seated in groove of hanger ball before attaching canopy to bracket Failure to properly seat tab in groove could cause damage to electrical wiring Figure 11 Outlet box Hanger bracket Canopy Canopy cover Screws Figure 12 9 ATTACHING THE FAN BLADES Step 1 Align t...

Страница 8: ...g ring and loosen the other 2 screws Do not remove Fig 15 Step 4 Place the key holes on the mounting plate over the 2 screws previously loosened from the mounting ring turn mounting plate until it locks in place at the narrow section of the key holes Secure by tightening the 2 screws previously loosened and the one previously removed Fig 15 Mounting ring Mounting plate Screws Screws LED light kit ...

Страница 9: ...ht kit over the two screws previously loosened from the mounting plate Turn the LED light kit until the LED light kit locks in place at the narrow section of the key holes Fig 16 Step 4 Securely tighten the two light kit mounting screws previously loosened and the one previously removed Fig 16 Step 5 Raise light shade up against the LED light kit and secure it to fan by turning light shade clockwi...

Страница 10: ...bulbs Fig 17 12 OPERATING INSTRUCTIONS Restore power to ceiling fan and test for proper operation Fig 18 A button Increase fan speed 6 speed max B button Decrease fan speed 1 speed minimal C 6 SPEED LED indicators Pressing and holding the button will increase the fan speed automatically through the speed settings and the incre ments will be denoted on the LED indica tors minimum speed low speed me...

Страница 11: ...1 through 4 in the up or down position making 16 different frequencies or combinations possible Anytime you change the frequency for a fan you must complete the pairing process as described above Beginning with the power off to all fans restore power to the first fan Select the desired frequency setting Complete the pairing process as described above Test the fan for proper operation Restore power...

Страница 12: ...ced beauty Cover small scratches with a light application of shoe polish 4 There is no need to oil your fan The motor has permanently lubricated bearings 13 CARE OF YOUR FAN IMPORTANT MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPT ANY REPAIRS REFER TO THE SECTION MAKING ELECTRICAL CONNECTIONS Figure 20 Figure 21 Speed settings for warm or cool weather depend on factors s...

Страница 13: ...6 Do not connect the fan with wall mounted variable speed control s 7 Make sure the upper canopy is a short distance from the ceiling It should not touch the ceiling 1 Do not connect the fan with wall mounted variable speed control s 2 Make sure the dip switches are set correctly 1 Check that all blade and blade arm screws are secure 2 Most fan wobbling problems are caused when blade levels are un...