3. SAFETY RULES

1.  To reduce the risk of electric shock, insure 

electricity has been turned off at the circuit 
breaker or fuse box before beginning.

2. All wiring must be in accordance with the 

National Electrical Code and local electrical 
codes. Electrical installation should be 
p e r f o r m e d  b y  a  q u a l i f i e d  l i c e n s e d 
electrician.

3. 

WARNING:

 To reduce the risk of electrical 

shock and fire, do not use this fan with any 
solid-state fan speed control device.

4. 

WARNING:

 To reduce the risk of fire, electric 

shock, or personal injury, mount to outlet 
box marked "acceptable for fan support of 
15.8 kg (35 lbs.) or less" and use mounting 
screws provided with the outlet box. Most 
outlet boxes commonly used for the 
support of light fixtures are not acceptable 
for fan support and may need to be 
replaced. Due to the complexity of the 
installation of this fan, a qualified licensed 
electrician is strongly recommended.

5.  The outlet box and support structure must 

be securely mounted and capable of 
reliably supporting a minimum of 50 
pounds. Use only UL Listed outlet boxes 
marked

 "FOR FAN SUPPORT".

6.  The fan must be mounted with a minimum 

of 7 feet clearance from the trailing edge 
of the blades to the floor.

7. Do not operate reversing switch while fan 

blades are in motion. Fan must be turned 
off and blades stopped before reversing 
blade  direction.

8. Avoid placing objects in the path of the 

blades.

9.   To avoid personal injury or damage to the 

fan and other items, be cautious when 
working around or cleaning the fan.

10. Do not use water or detergents when 

cleaning the fan or fan blades.  A dry dust 
cloth or lightly dampened cloth will be 
suitable for most cleaning.

11. After marking electrical connections, 

spliced conductors should be turned 
upward and pushed carefully up into 
outlet box. The wires should be spread 
apart with the grounded conductor and 
the equipment-grounding conductor on 
one side of the outlet box.

12. Electrical diagrams are reference only. Light 

kit that are not packed with the fan must be 
UL Listed and marked suitable for use with 
the model fan you are installing. Switches 
must be UL General Use Switches. Refer to 
the Instructions packaged with the light kits 
and switches for proper assembly.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK OR PERSONAL INJURY, MOUNT FAN 

TO OUTLET BOX MARKED 

"ACCEPTABLE 

FOR FAN SUPPORT".

WARNING

TO REDUCE THE RISK OF PERSONAL INJURY, 

DO NOT BEND THE BLADE BRACKETS (ALSO 

REFERRED TO AS FLANGES) DURING 

ASSEMBLY OR AFTER INSTALLATION. DO NOT 

INSERT OBJECTS IN THE PATH OF THE BLADES.

ATTENTION

 

Under the Energy Policy Act of 2005, 

federal regulations require all ceiling fans 

with light kits manufactured or imported 

after January 1, 2009, to limit the total 

wattage consumed by the light kit to 190 

watts. Therefore, this product is equipped 

with a 190W limiting device. If lamping 

exceeds 190 watts, the light kit will shut 

off automatically until the proper wattage 

of bulbs are installed. Reset the light kit by 

turning it off, replacing the bulbs with the 

correct wattage, and then turning the 

light kit back on.

Содержание 52-160-5RV-13

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V 60Hz UL LISTED MODEL AC 552 MODEL 52 160 5RV 13 CEILING FAN OWNER S MANUAL ...

Страница 2: ...bly j Glass shade k 3 x 40W candelabra bulbs l Pull chain and fobs 2 m Extra plastic plug n Package hardware 1 Mounting hardware screws 2 lock washers 2 star washers 2 wire nuts 3 wood screws 2 washers 2 2 Blade attachment hardware screws 16 fiber washers 16 3 Blade arm hardware screws with lock washers 11 4 Balance Kit Philips screw driver Blade screw driver 11 mm wrench Step ladder Wire cutters ...

Страница 3: ...e fan and other items be cautious when working around or cleaning the fan 10 Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning 11 After marking electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded cond...

Страница 4: ...weight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 Outlet bo...

Страница 5: ...th your outlet box Step 3 Remove the hitch pin lock pin and set screws from the top of the motor assembly Step 4 Route wires exiting from the top of the fan motor through the coupling cover canopy and then through the ball downrod Fig 6 Step 5 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Fig 6 Carefully insert the hitch pin through the holes...

Страница 6: ...e the ceiling canopy over the collar at the top of the motor Align the mounting holes with the holes in the motor and fasten using the screws and lock washers provided Fig 9 6 Tighten the mounting screws securely WARNING Failure to completely tighten the three screws in step 5 could result in fan loosening and possibly falling 7 Hang the fan on the hook of the hanger bracket Be certain that the ca...

Страница 7: ...re to the white neutral household wire Step 3 Connect the fan ground wire green to the household ground wire Step 4 After connecting the wires spread them apart so that the green and white wires are on one side of the outlet box and the black and the blue wires are on the other side Step 5 Turn the connecting nuts upward and push the wiring into the outlet box Figure 11 WARNING TO REDUCE THE RISK ...

Страница 8: ...Secure the canopy to the hanger bracket with the four screws with your fan CLOSE TO CEILING INSTALLATION Remove the fan from the hook on the hanger bracket Secure the canopy to the hanger bracket as shown in Figure 13 with four screws included with your fan Figure 12 Figure 13 Outlet box Hanger bracket Screws Outlet box Hanger bracket Ceiling canopy Screws Ceiling canopy ...

Страница 9: ...ssembly to motor using the screws supplied Fig 14 Figure 15 Figure 14 9 INSTALLATING THE MOUNTING PLATE Step 1 Remove the 1 of 3 screws from the mounting ring and loosen the other 2 screws Do not remove Step 2 Place the key holes on the mounting plate over the 2 screws previously loosened from the mounting ring turn mounting plate until it locks in place at the narrow section of the key holes Secu...

Страница 10: ...o the chain doesn t rub against any of the bulbs 10 INSTALLING THE LIGHT KIT NOTE Before starting installation disconnect the power by turning off the circuit breaker or removing the fuse at fuse box Turning power off using the fan switch is not sufficient to prevent electric shock 1 Remove the screws from the mounting plate under the fan motor 2 While holding the light kit assembly under your fan...

Страница 11: ...g 19 This allows you to set your air conditioner on a warmer setting without affecting your comfort Cool weather Reverse An upward airflow moves warm air off the ceiling area as shown in Fig 20 This allows you to set your heating unit on a cooler setting without affecting your comfort Figure 19 Figure 18 Figure 20 12 FAN WITHOUT LIGHT KIT OPTIONAL 1 Disassemble the switch housing from the light ki...

Страница 12: ...g the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing Do not use water when cleaning This could damage the motor or the wood or possibly cause an electrical shock 3 You can apply a light coat of furniture polish to the wood blades for additional protection and enhanced beauty Cover small scratches with a light application of shoe polish 4 There is no need to oil...

Страница 13: ...a short distance from the ceiling It should not touch the ceiling 1 This unit is equipped with a wattage limiting device Lamping in excess of 190 watts will disable your ceiling fan s light kit To reset your light kit you must turn the power off and re lamp keeping the wattage under 190 watts Restore power to your ceiling fan and continue normal operation 1 Check that all blade and blade arm screw...

Отзывы: