EN
9
9
Mounting the hood body
• Remove the metal grease filters by turning the handles
provided.
• Adjust the two screws
Vr
, on brackets
11a
, to a mini-
mum.
• Hook the hood canopy onto the two brackets
11a.
• From inside the hood canopy, adjust the screws
Vr
to
set the Hood Canopy level.
• Tighten the safety screws
12a
.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150 or
120mm, the choice of which is left to the installer.
To install a ø 150 pipe
• To install the dumper
10
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
To install a ø 120 pipe
• To install a ø 120 mm air exhaust connection, insert the
reducer flange
9
on the dumper
10
.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove any activated charcoal filters.
AIR OUTLET – RECIRCULATION VERSION
• Unfasten the 2 screws fixing the upper bracket
7.2.1
.
• Fasten the air outlet connector
15
in its place, using the
2 screws removed as above.
• Join the Connector
15
to the Hood canopy outlet using a
rigid or flexible pipe ø150 mm, selection of which is at
the discretion of the installation technician.
• Make sure that the Activated charcoal odour filter has
been fitted.