Savin C2525
Toner Replacement Process
Users open the front door of the Savin C2525 to access
both the toner and imaging unit. A plastic protective guard
must be removed before the imaging drum can be
accessed.
To replace the toner bottle, the bottle is simply pulled out of
its docking station. During replacement, BERTL analysts
experienced no toner spill. The individual toner docking
stations have different holes to prevent the incorrect toner
supply being entered in error.
The imaging drums are protected by an additional plastic
guard. To remove the guard, a plastic lock must first be
removed using a screwdriver. To access the four imaging
stations, a lever and front plate guard is lowered. Users can
slide out the unit in need of replacement.
The image drums can be cleaned using a brush that comes
with the unit. The brush is stored on the door by sliding into
a guide hole accompanying each imaging drum.