Saveometer 2652 Скачать руководство пользователя страница 18

 

 

 

 

 

18 

 

13   ABBREVIATED USER GUIDE 

To programme

 

To show more useful information

 

 

 
 
 
 

 

Modes 





 


10 
11 
12 
13 
14 
15 

16 

17 

18 
19 
20 

21 

 

Press top button for 5 seconds 
until display blinks. Chose mode 
using < or > & press S. Adjust 
settings using < or >. Press S 
again to finish. 

 

Setting 
Time/date 
12/24 hour clock 
dd/mm/yy choice 

Vary elec. Rates/& times/day 

Cost alert LED levels 
Zero total electricity costs

 

Erase all stored data  

 

This cannot be reversed! 

Messages 1 or 2 or off  

Set voltage  
Set CO2 rate /kWh  
Time signal sync 
Set time zone 
Use default settings  
Link a new display  
Select £ $ € or ¥ 

Select gas price per kWh 
Zero total gas costs 
Set gas Cu Ft or Cu Meters 
Gas conversion factor 

   Sync with your gas meter 
   Test gas transmit range 

 

 

 

 

Press 

 

10 

11 

12 

Each short press of the button will 

show the following:        

 

Display shows 

 

Back light turns on, if it is not  

already illuminated 

Total electricity cost since last reset  

Total gas cost - since last reset

 Electricity cost 

 last week 

 Electricity cost 

 last month 

 Electricity cost 

 last quarter 

 Electricity cost 

 last year 

 kWh used 

 current month 

 kWh hours used 

 this year 

 Kilograms CO

created

 

-

 

current month 

 Kilograms CO

2

 created - current year 

 

See “DONE”

 & the default display.  

 

 

User Guides are occasionally mislaid or lost. If this happens there are abbreviated instructions also printed 
on a small label at the back of the display, as well as brief guide printed on the underside of the display 
charging base. Alternatively, free copies are available from our web site at www.saveometer.com

 

Information about gas is printed in green and only applies once a gas transmitter has been installed

 

 

Содержание 2652

Страница 1: ... you to save money and our environment every day for years to come Your new Saveometer PSM is designed to work out of the box We recognise that many people like to enjoy new purchases immediately and frequently start reading the user guide as a last resort But on this occasion please take time to read this guide and you will soon discover that the Saveometer has very many useful money saving featu...

Страница 2: ...2 INDEX PAGE 1 Welcome 2 Index 3 What s in the box 4 Feature list 5 Getting Started 6 The Atomic clock 7 The Saveometer display 8 Accessing more information 9 How to change settings 10 Calculating your settings 11 Technical specification 12 Your guarantee 13 An abbreviated user guide 14 Typical sensor installations 15 A record of your chosen settings Saveometer display side view and support bracke...

Страница 3: ...isplay 14 Battery low T transmitter 15 Pence or Cents 16 This area is used to display useful information This includes a 30 day dynamic bar chart or graph of your electricity use the most recent day enters from the right hand side prompts when varying settings messages 3 WHAT S IN THE BOX 2 Three sockets to connect sensor clip jacks are underneath Up to 3 jacks may be connected at a time Display c...

Страница 4: ...aking it easy to see your cost trends at a glance Greenhouse gasses CO2 resulting from your electricity consumption may be displayed the Saveometer encourages thinking green as well as saving money Battery low indicators for transmitter T display D show when batteries are low Very low energy Eco friendly switching power supply The Saveometer PSM current sensor clip is efficient from half an amp up...

Страница 5: ... batteries are installed the display will initially show a default date a 28 day simulated bar chart and NO DATA indicating that data is not being received from your electricity meter If the display fails to show anything please check the batteries are correctly installed and or recharge them immediately as described above before going any further 2 Set the time date To set the clock and date pres...

Страница 6: ...vided The transmitter must be kept completely dry at all times 5 When the sensor clip has been correctly connected to the transmitter the display will stop showing NO DATA and show a default 28 day bar chart and also how much per hour you are currently spending on electricity If NO DATA continues to show check the sensor clip jack is properly inserted If NO DATA still continues to show it may be n...

Страница 7: ...ndar from transmitters located worldwide These signals are always strongest at night and they enable clocks to achieve an accuracy of better than 1 second in 1000 years Thick brick or concrete walls basements and close proximity to other electronic apparatus especially power supplies may inhibit receiving atomic clock radio signals To optimise atomic clock radio signals it is best to extend the po...

Страница 8: ...how after only a few days with the recent past day s cost trend always showing on the right hand side of the display The bar chart below shows a 30 day example of a user s rather erratic electricity consumption The battery low icons only appear when either the electricity transmitter batteries icon followed by T or the display batteries icon followed by D need recharging For the transmitter simply...

Страница 9: ...his guide 3 Total Gas A gas transmitter will be required to be purchased This mode shows the total cost of gas since you last reset the Saveometer A symbol denoting gas is also shown 4 LAST WEEK The cost of electricity used in the previous week ending on Saturday at 12 00 pm 5 LAST MONTH Cost of electricity used in previous calendar month 6 LAST 1 4 Cost of electricity used in previous calendar qu...

Страница 10: ...g a separate mode and to change any setting the procedure is identical How to change settings 1 Press the top button for 5 seconds until display shows TIME DATE release button and mode 01 will blink where the temperature is normally seen 2 Use the and keys to select the mode you require 3 Press S to select the mode 4 Use the and keys to vary the values as you wish 5 Press S to finish when the disp...

Страница 11: ...ng the date the display will show SURE in the sequence to warn you the bar graph may be reset to an earlier date To accept press S in the normal way If reset to a later date the bar chart will reset to default and no other data will be lost When changing batteries seldom the time resets to nearest hour will reset automatically or can be manually re set Time date default settings vary according to ...

Страница 12: ...E that you really do wish to proceed to zero the total cost by pressing S 000 00 7 Erase ALL acquired stored data This feature is seldom used and is primarily for when a Saveometer is reinstalled in a new location such as when moving home or business This enables you to erase all data that your Saveometer has ever acquired since it was first installed This mode will remove your bar chart all costs...

Страница 13: ...Then select mode 14 and press S you will see the word register on the display Within 60 seconds press the green button on the transmitter until the red LED starts to blink release The red LED will soon stop blinking the new display will have been linked to the transmitter In about 10 seconds the display will show your current electricity cost per hour You may connect up to 25 displays to each tran...

Страница 14: ...eplaced by the data received from the gas transmitter If no signal is received Gas Rx will continue to show To finish press S again to exit this mode You may find it useful to use a cordless or cellular phone to communicate when using this feature as the gas transmitter and a Saveometer display may be far apart n a Gas transmitters are sealed units and contain high quality long life lithium batter...

Страница 15: ...tal 866 50 Total Kilowatt hours kWh charged were 27772 866 50 3 12p average cost per kilowatt hour 27772 If in doubt about the appropriate rate to set we suggest that you use a rate that is a little higher than your calculations in that way there will be no unpleasant surprises when your bill eventually arrives For more advice on setting your electricity and gas rates there is more useful informat...

Страница 16: ...by 110uA Operation 25mA 1 mA average Battery Low indication Battery low indication at display for both the transmitter and display Battery Recharging Use only the transmitter display compatible charging base Remove connecting jack from transmitter before placing in charging base Power Supply Eco friendly very low power consumption Switching Mode SMPS Use only supplied power supply model S005CB0720...

Страница 17: ...t Meter in the event of any problems contact us at customersupport saveometer com Do not immerse in water or any other liquids or locate in a wet or damp environment Clean only with a soft duster or slightly damp cloth do not use a spray of any sort Do not expose to heat flames water vapour rain snow steamy conditions or extreme cold Do not hit strike or drop the equipment or leave in direct sunli...

Страница 18: ...it range Press 1 2 3 4 5 6 7 8 9 10 11 12 Each short press of the button will show the following Display shows Back light turns on if it is not already illuminated Total electricity cost since last reset Total gas cost since last reset Electricity cost last week Electricity cost last month Electricity cost last quarter Electricity cost last year kWh used current month kWh hours used this year Kilo...

Страница 19: ...a Start time C rate n a Start time D rate n a 5 Cost alert LED s Off Less than 4p hr Green Over 4p hr Yellow Over 20p hr Red Over 30p hr Flashing Red Over 40p hr 6 Zero total electricity cost n a 7 Erase stored data n a 10 CO2 created 0 43 Kg kWh 14 Reset to default values n a 17 Set gas cost per kWh 3 4p kWh 18 Zero total gas cost n a 19 Set gas conversion factor s 0 32 CuFt to kWh 11 27 CuM to k...

Страница 20: ...Failure to do so may damage the switch mode power supply Electricity sensor clip with three meter connecting wire and jack If the Saveometer is installed in a large house or in commercial premises it is likely that the electricity is a three phase supply A separate sensor clip is required for each phase Three sensor clips may be attached to a single transmitter NEW Gas sensor transmitter Your Save...

Отзывы: