16
11 TECHNICAL SPECIFICATION- MODEL S2652e
Processors:
8Bit – 16 MIPS RISC Microcontroller
Memory:
Non-volatile EEPROM – data retention more than 20 years
Information:
Zones:
Up to 4 different cost rate periods per day
Currency:
LCD Display:
High quality FSTN type
System Configuration:
Up to 50 Display Units can be registered to transmitter
Atomic Clock:
Multiple Bands – sync for WWVB, DCF77, MSF and JJY.
Radio Frequency:
868 MHz ISM Band
Transmitter/Display Range
80 meters – open area; 40 meters – indoors
Temperature:
+/- 1 deg C. Humidity: +/-5% Relative Humidity
Weather Forecast Status
Cloudy, shower/rain, occasional Sunshine, and Sunny
Current Measurement:
0.3A – 100A (Ampere), cumulative 3-phrase measurement is supported
by transmitter. Accuracy depends on the variables you have set.
Current (RMS) accuracy
- 0.3A – 1A <5% 1A – 100A <3%
Energy Consumption alert
5 levels of Ultra-bright LED’s indicate current energy consumption
Off, Green, amber, red and flashing red.
Servicing
Do not attempt to service any part yourself.
Openining or removing
covers may expose you to dangerour voltages or other risks and voids all
warranties. Refer all servicing only to qualified engineers at Eco
1
Limited.
Batteries
Use only supplied NiMH rechargeable batteries
(rating1.2V 1000mAh)
Warning
–incorrect batteries may result in explosion or fire hazard
For replacements contact Eco1 Limited or at www.saveometer.com
Battery Consumption: Transmitter Standby: 60uA Operation: 45mA
Display Unit Standby: 110uA Operation: 25mA & 1 mA (average)
Battery Low indication
Battery low indication at display for both the transmitter and display
Battery Recharging
Use only the transmitter & display compatible charging base
. Remove
connecting jack from transmitter before placing in charging base.
Power Supply
Eco-friendly (very low power consumption) Switching Mode (SMPS)
Use only supplied power supply (model
S005CB0720050
)
with input: 100 – 240V; 50/60Hz; 150 mA; Output 9V DC 500mA
Operational Temperature: 5 deg C – 45 deg C (41 deg F – 113 deg F) at 85% relative humidity
Dimensions:
Transmitter 70 mm W x 115H x 35 D, weight 150g , Display unit 99W x 157H
(Weights with batteries)
x 35 D weight 341g, charging base 130W x 47H x 125D mm, weight 154g
Cleaning
Only clean the transmitter and display and charger base using a dry
cloth
. Do not use aerosol or liquid cleaners.
Keep display air vents clean &
do not block the air vents in any way
Safety
: EN60 950-01 2002 & EN503712002
EMC
: EN301 330-22006
Radio
: EN300 220-22007
Complies with the essential requirements of
Council Directive 99/05/EC
Copies of all compliance certificates available on written request
If the Saveometer or any part thereof is used in a manner not specified herein the protection provided
by the Saveometer may be impaired.
Final manufacture is by a carefully selected ISO9001:2000
approved factory in the PRC. Components are from the UK, Japan, the USA, Korea and elsewhere.
Conforms to the adjacent
technical & standards
Warning
: Do not use
non recharegeable
batteries
Warning
: Adopt safe procedures when
working on hazardous live installations,
like when fitting or removing a current
sensor