accuracy of the time and date,  & is capable of receiving signals 
from  several  distant  radio  beacons.  This  mode  enables  a 
particular beacon to be selected.  The signals available are 

DCF

 

in  Germany  which  covers  most  of  Europe: 

  MSF

  located  in 

Cumbria  which  covers  all  the  UK: 

WWVB

  in  America  which 

covers the USA, Canada and the Middle East & 

JJY

 for Japan and 

parts of China.  If there is no signal the radio icon will extinguish, 
but the clock will still keep excellent time anyway 

12 

Set  time  zone

.  It  is  also  unlikely  that  you  will  ever  need  to  use 

this  mode.  As  mentioned  in  11  above  the  Saveometer  receives 
radio  signals  from  one  of  several  geographically  spread 
transmitters,  some  of  which  may  give  a  time  that  is  not  in  line 
with  the  location  where  the  Saveometer  is  located.  When  this 
occurs  the  time  may  be  “offset”  by  precisely  one  or  several 
hours, either forward or backwards. This enables users to make 
an  appropriate  correction,  in  one  hour  increments  or 
decrements, so that the correct time is always shown.  

0 (Zero) 

13 

Reset  to  default  values

.  This  mode  resets 

all

  the  variable 

settings  that  you  have  made  to  the  original  factory  default 
values – as listed in the right hand column. 

Not 
applicable 

14 

Linking  a  display

  to  an  existing  electricity  transmitter.  Install 

fully  charged  batteries,  &  set  the  time/date  manually  (mode  1). 
Then  select  mode  14  and  press 

S

 

&  you  will  see  the  word 

“register”  on  the  display.  Within 60  seconds  press  the  green 
button  on  the  transmitter  until  the  red  LED  starts  to  blink  & 
release.  The  red  LED  will  soon  stop  blinking  &  the  new  display 
will have been linked to the transmitter. In about 10 seconds the 
display will show your current electricity cost per hour. You may 
connect up to 25 displays to each transmitter, and they will read 
identically.  

Not 
applicable 

15 

Currency choice 

– these are 

£ $  € 

and

 ¥

 

£ 

Modes 16 – 21 require a separate gas transmitter. When a gas transmitter is connected 
the following modes become available, and until that time these modes remain hidden.

 

16 

Set  gas  price

  (per  Kilowatt  Hour  or  kWh).  Gas  prices  vary  between 

suppliers & you may wish to alter the default setting. For the best way to 
work out your appropriate setting please to refer to page 15.

 

 

3.4p/kWh 

17 

Zero the total cost of gas used. 

 This total may be reset to zero at any 

time. For example, some users may wish to monitor their gas costs over 
6 month periods, while some commercial activities using more gas may 
chose  to  monitor  costs  every  day,  or  week  or  fortnight.  This  feature 
provides a total of your gas costs over any period of your choice. Zeroing 
total  costs  does  not  interfere  with  any  other  stored  data. 

As  a  safety 

measure  to  avoid  accidental  erasure,  you  will  be  prompted  by  the  lower 
display during this mode to hold the > button  down for 6 seconds, & then 
confirm (see word “SURE?”) you really do wish to proceed to zero the total 
cost by pressing 

S  

 

n/a 

Содержание 2652

Страница 1: ... you to save money and our environment every day for years to come Your new Saveometer PSM is designed to work out of the box We recognise that many people like to enjoy new purchases immediately and frequently start reading the user guide as a last resort But on this occasion please take time to read this guide and you will soon discover that the Saveometer has very many useful money saving featu...

Страница 2: ...2 INDEX PAGE 1 Welcome 2 Index 3 What s in the box 4 Feature list 5 Getting Started 6 The Atomic clock 7 The Saveometer display 8 Accessing more information 9 How to change settings 10 Calculating your settings 11 Technical specification 12 Your guarantee 13 An abbreviated user guide 14 Typical sensor installations 15 A record of your chosen settings Saveometer display side view and support bracke...

Страница 3: ...isplay 14 Battery low T transmitter 15 Pence or Cents 16 This area is used to display useful information This includes a 30 day dynamic bar chart or graph of your electricity use the most recent day enters from the right hand side prompts when varying settings messages 3 WHAT S IN THE BOX 2 Three sockets to connect sensor clip jacks are underneath Up to 3 jacks may be connected at a time Display c...

Страница 4: ...aking it easy to see your cost trends at a glance Greenhouse gasses CO2 resulting from your electricity consumption may be displayed the Saveometer encourages thinking green as well as saving money Battery low indicators for transmitter T display D show when batteries are low Very low energy Eco friendly switching power supply The Saveometer PSM current sensor clip is efficient from half an amp up...

Страница 5: ... batteries are installed the display will initially show a default date a 28 day simulated bar chart and NO DATA indicating that data is not being received from your electricity meter If the display fails to show anything please check the batteries are correctly installed and or recharge them immediately as described above before going any further 2 Set the time date To set the clock and date pres...

Страница 6: ...vided The transmitter must be kept completely dry at all times 5 When the sensor clip has been correctly connected to the transmitter the display will stop showing NO DATA and show a default 28 day bar chart and also how much per hour you are currently spending on electricity If NO DATA continues to show check the sensor clip jack is properly inserted If NO DATA still continues to show it may be n...

Страница 7: ...ndar from transmitters located worldwide These signals are always strongest at night and they enable clocks to achieve an accuracy of better than 1 second in 1000 years Thick brick or concrete walls basements and close proximity to other electronic apparatus especially power supplies may inhibit receiving atomic clock radio signals To optimise atomic clock radio signals it is best to extend the po...

Страница 8: ...how after only a few days with the recent past day s cost trend always showing on the right hand side of the display The bar chart below shows a 30 day example of a user s rather erratic electricity consumption The battery low icons only appear when either the electricity transmitter batteries icon followed by T or the display batteries icon followed by D need recharging For the transmitter simply...

Страница 9: ...his guide 3 Total Gas A gas transmitter will be required to be purchased This mode shows the total cost of gas since you last reset the Saveometer A symbol denoting gas is also shown 4 LAST WEEK The cost of electricity used in the previous week ending on Saturday at 12 00 pm 5 LAST MONTH Cost of electricity used in previous calendar month 6 LAST 1 4 Cost of electricity used in previous calendar qu...

Страница 10: ...g a separate mode and to change any setting the procedure is identical How to change settings 1 Press the top button for 5 seconds until display shows TIME DATE release button and mode 01 will blink where the temperature is normally seen 2 Use the and keys to select the mode you require 3 Press S to select the mode 4 Use the and keys to vary the values as you wish 5 Press S to finish when the disp...

Страница 11: ...ng the date the display will show SURE in the sequence to warn you the bar graph may be reset to an earlier date To accept press S in the normal way If reset to a later date the bar chart will reset to default and no other data will be lost When changing batteries seldom the time resets to nearest hour will reset automatically or can be manually re set Time date default settings vary according to ...

Страница 12: ...E that you really do wish to proceed to zero the total cost by pressing S 000 00 7 Erase ALL acquired stored data This feature is seldom used and is primarily for when a Saveometer is reinstalled in a new location such as when moving home or business This enables you to erase all data that your Saveometer has ever acquired since it was first installed This mode will remove your bar chart all costs...

Страница 13: ...Then select mode 14 and press S you will see the word register on the display Within 60 seconds press the green button on the transmitter until the red LED starts to blink release The red LED will soon stop blinking the new display will have been linked to the transmitter In about 10 seconds the display will show your current electricity cost per hour You may connect up to 25 displays to each tran...

Страница 14: ...eplaced by the data received from the gas transmitter If no signal is received Gas Rx will continue to show To finish press S again to exit this mode You may find it useful to use a cordless or cellular phone to communicate when using this feature as the gas transmitter and a Saveometer display may be far apart n a Gas transmitters are sealed units and contain high quality long life lithium batter...

Страница 15: ...tal 866 50 Total Kilowatt hours kWh charged were 27772 866 50 3 12p average cost per kilowatt hour 27772 If in doubt about the appropriate rate to set we suggest that you use a rate that is a little higher than your calculations in that way there will be no unpleasant surprises when your bill eventually arrives For more advice on setting your electricity and gas rates there is more useful informat...

Страница 16: ...by 110uA Operation 25mA 1 mA average Battery Low indication Battery low indication at display for both the transmitter and display Battery Recharging Use only the transmitter display compatible charging base Remove connecting jack from transmitter before placing in charging base Power Supply Eco friendly very low power consumption Switching Mode SMPS Use only supplied power supply model S005CB0720...

Страница 17: ...t Meter in the event of any problems contact us at customersupport saveometer com Do not immerse in water or any other liquids or locate in a wet or damp environment Clean only with a soft duster or slightly damp cloth do not use a spray of any sort Do not expose to heat flames water vapour rain snow steamy conditions or extreme cold Do not hit strike or drop the equipment or leave in direct sunli...

Страница 18: ...it range Press 1 2 3 4 5 6 7 8 9 10 11 12 Each short press of the button will show the following Display shows Back light turns on if it is not already illuminated Total electricity cost since last reset Total gas cost since last reset Electricity cost last week Electricity cost last month Electricity cost last quarter Electricity cost last year kWh used current month kWh hours used this year Kilo...

Страница 19: ...a Start time C rate n a Start time D rate n a 5 Cost alert LED s Off Less than 4p hr Green Over 4p hr Yellow Over 20p hr Red Over 30p hr Flashing Red Over 40p hr 6 Zero total electricity cost n a 7 Erase stored data n a 10 CO2 created 0 43 Kg kWh 14 Reset to default values n a 17 Set gas cost per kWh 3 4p kWh 18 Zero total gas cost n a 19 Set gas conversion factor s 0 32 CuFt to kWh 11 27 CuM to k...

Страница 20: ...Failure to do so may damage the switch mode power supply Electricity sensor clip with three meter connecting wire and jack If the Saveometer is installed in a large house or in commercial premises it is likely that the electricity is a three phase supply A separate sensor clip is required for each phase Three sensor clips may be attached to a single transmitter NEW Gas sensor transmitter Your Save...

Отзывы: