MW-1000™ User Guide
11
5
MW-1000™ Getting Started
This section describes the procedures to get the
MW-1000™
started after installation and power
up.
5.1 Accessing Methods
After power up, the
MW-1000™
comes up with a default IP of 192.168.100.1.
The
MW-1000™
can be accessed from any PC or laptop using ssh.
To Access using SSH:
Password:5@G3p9axINJA
5.2 Status Indication
The following table displays the details about the LED status indicators
:
LED Name
Indication
Description
PWR
On
Off
The device is powered on.
The device is powered off.
TX
Off
Blinking (As per the Tx rate)
BSMs are not transmitting.
BSMs are transmitting.
USB
On
Off
Mounted
Not mounted
5.3 Default Configuration
DSRC radio 1 (ath0)
: This radio is configured in channel switching mode to listen for WSAs and
connect to RSE if the requested service is available.
DSRC radio 2 (ath1)
: This radio is configured in the continuous channel access for channel 172
which is configured by default. Different channel can be used by changing configuration file. BSM
transmission and reception happens on this radio.