MW-1000™ User Guide
26
/etc/config/syslog
A reboot or a manual system state cycle is needed for the change to take effect.
Only the following parameters in the configuration file are recommended to be changed by the
user, if desired.
The user should not change other parameters that are not documented here:
Configuration Item
Value
Description
config syslogd
option enable
1
1: Enable logging system-logs
0: Disable logging system-logs
option ipaddr
In lab-conditions, provide remote-machine
IP-address to remotely log the MW-
1000’s
syslog information.
option port
Remote-
machine’s port-number, for logging
syslog information
option size
256
Maximum file size in KB, 0 unlimited.
option type
option loglevel
7
0: Log only system-critical messages
7: Log all information messages
option mark
0
option directory
/nojournal/systemlogs/ Specify the disc-location for writing syslogs
option time
0
Maximum time a file can grow (
minutes
), 0
unlimited. Post the max-time, a new file is
generated.
option
disc_capacity
70
The percentage of maximum disk capacity
allowed. All syslog logging is disabled once
the configured disc-capacity is reached.
Note
:
MW-1000™
logs SML files into USB drive while changing option log_dir to
/mnt/usbdrive/systemlogs