Appendix

Product Conversions

This document is a chart used to upgrade legacy LiteTouch products to Savant SmartLighting products.

LiteTouch

Savant

Comments

Controllers

Controllers

Controllers

FIVEk

Standard CCU

Compact CCU

SSL-P018

SSL-P002

All controllers are replaced with the SSLs.  

FIVEk must be replaced by an SSL and an 

SKL (to power keypads). Power supplies are 

not needed in the enclosures.

Keypads

Keypads

Keypads

S

H

E

Capri

Coastal

Hybrids

Metropolitan

G2

Circa

Echo

1000/2600 Series

Metropolitan

Circa

Echo

As of January 1, 2013, we have three 

keypad models of various configurations.

Enclosures

Enclosures

Enclosures

08-8024-21 4 Module Enclosure

ENC-4000-00

08-8024-23 4 Module Enc. Surface Mount Lid

ENC-S4LID-00

08-8024-24 4 Module Enc. Recess Mount Lid

ENC-R4LID-00

08-8025-21 2 Module Enclosure

ENC-2000-00

08-8025-23 2 Module Enc. Surface Mount Lid

ENC-S2LID-00

08-8025-24 2 Module Enc. Recess Mount Lid

ENC-R2LID-00

140915   009-0885-01  Savant SmartLighting Control Conversion Application 

18    of    22

Содержание SmartLighting

Страница 1: ...Number 009 0885 01 1 of 22 Copyright 2014 Savant Systems LLC SAVANT and RacePoint Blueprint are trademarks of Savant Systems LLC All brand names product names and trademarks are the property of their...

Страница 2: ...les 8 Removing and Replacing a Transorb Board 9 Installing a SmartLighting Controller 10 Connecting a Savant SmartLighting Controller to an SKL 1000 11 Installing a Savant Keypad Link 13 Connecting a...

Страница 3: ...tant Savant SmartLighting products have been redesigned to be more efficient and are automatically integrated Some of the older legacy out of warranty products may no longer be compatible with this ne...

Страница 4: ...rb boards 5 Install SmartLighting controller 6 Install Savant Keypad Links 7 Confirm the rewiring as follows New transorb board connected to SmartLighting controller via Cat 5 5e 6 cable New transorb...

Страница 5: ...RESS MANUAL ON ACTIVE OUTPUT LEDS MANUAL REMOTE ON INPUT120 VAC 60 Hz LOAD TYPE LOAD TYPE TUNGSTEN TUNGSTEN RELAY RATING RELAY RATING 15 A 120 VAC MAX PER OUTPUT 20 A 120 VAC MAX PER OUTPUT 40 A 120 V...

Страница 6: ...andard and compact CCUs do not use prg files The standard and compact CCU definition files def and cdf respectively must be converted to prg files Note that the CCU communicates with LiteWare using ei...

Страница 7: ...roller Type previously selected 7 Click From Controller 8 Browse to the location where you would like the extracted prg file stored and click Save The status pane in the Control Panel will show the pr...

Страница 8: ...d into LiteWare as an LW4 file 4 Click the Job Parameters tab 5 Under Controller Selection for Type select either SSL P018 or SSL P002 from the drop down list 6 From the main menu select File Save As...

Страница 9: ...than eight enclosures or when you have mul tiple enclosure locations you can string enclosures together to reduce the number of data homeruns to the CCU While this helps to simplify the wiring you sh...

Страница 10: ...module which is connected to the tran sorb board via the 5 pin connector 0 1 2 3 42 In large installations more than eight enclosures or when you have mul tiple enclosure locations you can string encl...

Страница 11: ...n the SmartLighting system you must configure the SSL P002 or SSL P018 to communicate using the same serial port standard By default the SKL 1000 uses RS 232 The SSL P002 or SSL P018 use RS 422 To set...

Страница 12: ...ect the Unique ID UID that matches the UID on the sticker of the SSL P018 or the SSL P002 3 Open a browser and enter the IP address of the SSL P018 or the SSL P002 4 Select Serial Ports on the sidebar...

Страница 13: ...not compliant with the new device rewiring or other reconfiguration will be necessary To connect the SKL 4000 to a SmartLighting controller SSL P018 or SSL P002 do the following 1 Using Cat 5 5e 6 ca...

Страница 14: ...ion bus ports circled in the next figure 5 To use the bus ports for connecting to keypads splice the 16 AWG or 18 AWG wiring and attach the wires to the three pin connector based on the following posi...

Страница 15: ...n boxes plaster or tile rings are not acceptable In new construction installations for example a single gang backbox model P 241 supplied by Allied Moulded Products would accommodate a Savant keypad A...

Страница 16: ...martLighting controller The SmartLighting controller communicates with LiteWare using an Ethernet connection To export the LiteWare prg file to an SSL P018 or SSL P002 do the following 1 Open LiteWare...

Страница 17: ...6 Confirm the TCP IP Settings IP Address and Port 7 Click To Controller 8 Browse to the prg file that you previously extracted from the CCU and click Open The status pane in the Control Panel will sho...

Страница 18: ...eypads Keypads S H E Capri Coastal Hybrids Metropolitan G2 Circa Echo 1000 2600 Series Metropolitan Circa Echo As of January 1 2013 we have three keypad models of various configurations Enclosures Enc...

Страница 19: ...8 2150 03 0 10 VDC 277V MIXED 007 PS and LV Relay MIXED 008 PS and Mom D I Module MIXED 009 PS and Maint D I Module MIXED 004 LV Relay and Mom D I Module MIXED 005 LV Relay and Maint D I Module MIXED...

Страница 20: ...porated AirPlay Apple AirPort Express AirPort Extreme Apple TV Apple Remote Desktop FireWire iMac iTunes iPad iPad mini iPhone iPod touch MacBook Mac and OS X are trademarks or trade names of Apple In...

Страница 21: ...document Caution describes a situation that may cause damage to the equipment Warning In this document Warning describes a situation that may present a physical danger to the installer or end user Ele...

Страница 22: ...he provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience...

Отзывы: