Sauter Components LRA 4 Series Скачать руководство пользователя страница 1

 

 

45.016/1

 

 

 

Sauter Components 

LRA 4**: Electronic room operating unit (868 MHz) 

How energy efficiency is improved 

Individual, optimised energy use through precise adherence to setpoint. 

Areas of use 

For single-room control in residential and commercial  properties, with wireless, bi-directional data 

transmission. 

Features 

  Room operating unit with bi-directional wireless transmission for heating/cooling 

  Transmission frequency 868 MHz, encoded 

  NTC sensor 

  Easy addressing, parameterisation and monitoring using sensor buttons 

  Large TFT LCD, black on grey, 32 × 38 mm 

  Integrated and configurable time programme 

  Heating/cooling change-over using a room operating unit or via the input on the controller 

  Party function and additional functions can be selected 

  Room operating unit can be configured as an additional sensor 

  Connection for floor, room or outside-temperature sensor 

  Contemporary design 

Technical description 

  Flat housing of white (RAL9016) or black (RAL9005) thermoplastic 

  Temperature range 5…30 °C 

  With settable frost-protection facility, factory setting 8 °C 

  Suitable for wall mounting and recessed junction box 

  Standard battery 2 × 1.5 V AAA 

 

 

T

Y10164

 

Type 

Colour 

Humidity range

 

% rh 

LRA420R K104

 

white 

– 

LRA420R K124

 

black 

– 

LRA450R K104

 

white 

5…95 

LRA450R K124

 

black 

5…95 

Setting range 

5...30 °C 

Perm. ambient temperature 

0...55 °C 

Setting accuracy 

±

0.1 K 

Perm. ambient humidity 

5…80% rh 

Sensor 

NTC 10 k

 

 

 

 

 

Weight 

0.13 kg 

Humidity accuracy 

±3.5% rh at 55% rh, 23 °C   

 

Hysteresis (average) 

> 3% rh 

Ingress protection 

IP 20 (EN 60529) 

 

 

Protection class 

III (EN 60730) 

Radio frequency 

868.3 MHz 

CE conformity as per: 

 

Transmission power 

13 mW (self-adjusting) 

R&TTE 1999/5/EG 

EN 300220-1 

Range 

1)

 

approx. 50 m 

 

EN 300220-3 

Data transmission 

every 10 minutes 

 

 

Power supply 

2 × AAA 1.5 V 

2)

 

Dimension drawing 

M11485

 

 

 

 

Cover plate 

M11487

 

 

 

 

Outside-temperature 

sensor 

M11492

 

 

 

Fitting instructions 

P100009964 

 

 

 

 

 

 

1)

 

In standard buildings or houses, depending on the ambient conditions, 40 m in buildings, 200...300 m in open areas (depending on obstruc-
tions and local sources of interference)

 

2) 

Supplied with the unit

 

 

 

 Accessories

 

0313367001 

Cable-type NTC sensor, 10 k

, 1.5 m, for floor or outside temperature, max. 70 °C

 

0313367003 

Cable-type NTC sensor, 10 k

, 3 m, for floor or outside temperature, max. 70 °C

 

0450232001 

Outside-temperature NTC sensor, 10 k

, in housing, -50…+90 °C, IP43, connected via two 

screw terminals, see fitting instructions P100011523 

0450241001 

Cover plate, white (RAL 9016), dimensions 138 mm × 72.5 mm

 

0450541021 

Cover plate, black (RAL 9005), dimensions 138 mm × 72.5 mm

 

 

 

*)

 

Dimension drawing or wiring diagram is available under the same number

 

 

 

7145016003  01 

Содержание LRA 4 Series

Страница 1: ...RA420R K124 black LRA450R K104 white 5 95 LRA450R K124 black 5 95 Setting range 5 30 C Perm ambient temperature 0 55 C Setting accuracy 0 1 K Perm ambient humidity 5 80 rh Sensor NTC 10 kΩ Weight 0 13 kg Humidity accuracy 3 5 rh at 55 rh 23 C Hysteresis average 3 rh Ingress protection IP 20 EN 60529 Protection class III EN 60730 Radio frequency 868 3 MHz CE conformity as per Transmission power 13 ...

Страница 2: ...control is possible without any additional settings If a cooling command is entered on the controller via the C O input cooling control starts automatically The cooling symbol is displayed on the room operating unit Other applications such as cooling via the master room operating unit and special function settings for hotels or public buildings can be set by means of the service parameters Enginee...

Страница 3: ... by pressing the or button again After 5 s or immediately after the OK button is pressed the selected setpoint is automatically sent to the wireless controller and saved there After that the actual temperature value is retrieved every 10 minutes By pressing the Menu button again it is possible to switch between the frost protection mode Off ECO normal operation or the time programme If the room op...

Страница 4: ...odes frost protection reduced operation normal operation time programme heating or cooling Select parameter menu mode Change setpoint Save value Confirm selection Change time Cancel Addressing Test addressing Lock unlock manual operation Select function or display directly Function Heating or cooling party function has priority over all other functions Over ride is active for the time set here bet...

Страница 5: ...ated humidity sensor 65 55 P SE Service parameters The service parameters are protected by a password set at 1 2 3 4 at the factory Parameter P SE comes after parameter P 11 If the OK button is pressed the code is queried Each number must be confirmed by pressing OK The first service parameter is P 20 If you press the OK button you are taken to the P 20 parameter list Pressing the Escape button ta...

Страница 6: ...ireless room operating unit 0 Parameters that are specific to the installation and the topology Factory setting P 51 Set priorities for the heating cooling change over and for the heating cooling output or burner control 0 P 52 Activate or deactivate the Optimised time programme function 0 deactivated P 53 Set the type of communication between wireless controllers options radio or bus 0 Control pa...

Страница 7: ...LRA4 45 016 7 Sauter Components Cover plate Outside temperature sensor Printed in Switzerland Subject to changes Fr Sauter AG CH 4016 Basle 7145016003 01 ...

Отзывы: