Overview of display and sensor buttons 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1  General information such as battery status, energy-saving mode, alarms for dew point and window 

contacts, radio connection, general alarm, locking, weekdays for time programme 

2  Temperature setpoint and actual value, time, time programme, indoor, outdoor and floor temperature 

3  Auxiliary texts for parameterisation 

4  Operating modes 

5  Confirm changed values, confirm selection 

6  Activate menu mode, select menus and parameters 

7  Change setpoints, time, date and other values; select the time programme 

8  Function button, can be set using parameter P-10 

9  Cancel: leave current parameter or menu 

 

Sensor buttons  Description 

 

Activate operation with any sensor button. 

 

Selection button 
Activate menu mode. 
Select operating mode. Possible operating modes: frost protection, reduced 

operation, normal operation, time programme, heating or cooling 
Select parameter (menu mode). 

 

Change setpoint. 

 

Save value. 
Confirm selection. 

 

Change time.

 

 

Cancel. 

 

Addressing. 
Test addressing. 

 

Lock/unlock manual operation. 

 

Select function or display directly 

Function: 

Heating or cooling (party function) has priority over all other functions. Over-

ride is active for the time set here, between 1 hour and 9 hours. On the 

display, P appears in front of the actual value. 

Function/display: 

Depending on the setting selected for parameter P-10, pressing the sensor 

button executes one of the following functions: 

  Immediate change-over between heating and cooling, and display of 

room temperature. 

  Immediate display of the floor temperature. 

  Immediate display of the outside temperature. 

  Immediate display of the relative humidity (optional). 

 

If a function other than the 'party function' is set using parameter P-10, this 

function still becomes active by pressing the sensor button for 5 seconds. 

 

7145016003  01 

Содержание LRA 4 Series

Страница 1: ...RA420R K124 black LRA450R K104 white 5 95 LRA450R K124 black 5 95 Setting range 5 30 C Perm ambient temperature 0 55 C Setting accuracy 0 1 K Perm ambient humidity 5 80 rh Sensor NTC 10 kΩ Weight 0 13 kg Humidity accuracy 3 5 rh at 55 rh 23 C Hysteresis average 3 rh Ingress protection IP 20 EN 60529 Protection class III EN 60730 Radio frequency 868 3 MHz CE conformity as per Transmission power 13 ...

Страница 2: ...control is possible without any additional settings If a cooling command is entered on the controller via the C O input cooling control starts automatically The cooling symbol is displayed on the room operating unit Other applications such as cooling via the master room operating unit and special function settings for hotels or public buildings can be set by means of the service parameters Enginee...

Страница 3: ... by pressing the or button again After 5 s or immediately after the OK button is pressed the selected setpoint is automatically sent to the wireless controller and saved there After that the actual temperature value is retrieved every 10 minutes By pressing the Menu button again it is possible to switch between the frost protection mode Off ECO normal operation or the time programme If the room op...

Страница 4: ...odes frost protection reduced operation normal operation time programme heating or cooling Select parameter menu mode Change setpoint Save value Confirm selection Change time Cancel Addressing Test addressing Lock unlock manual operation Select function or display directly Function Heating or cooling party function has priority over all other functions Over ride is active for the time set here bet...

Страница 5: ...ated humidity sensor 65 55 P SE Service parameters The service parameters are protected by a password set at 1 2 3 4 at the factory Parameter P SE comes after parameter P 11 If the OK button is pressed the code is queried Each number must be confirmed by pressing OK The first service parameter is P 20 If you press the OK button you are taken to the P 20 parameter list Pressing the Escape button ta...

Страница 6: ...ireless room operating unit 0 Parameters that are specific to the installation and the topology Factory setting P 51 Set priorities for the heating cooling change over and for the heating cooling output or burner control 0 P 52 Activate or deactivate the Optimised time programme function 0 deactivated P 53 Set the type of communication between wireless controllers options radio or bus 0 Control pa...

Страница 7: ...LRA4 45 016 7 Sauter Components Cover plate Outside temperature sensor Printed in Switzerland Subject to changes Fr Sauter AG CH 4016 Basle 7145016003 01 ...

Отзывы: