13
3. INSTALLATION INSTRUCTIONS
3.1. Before installation
Installation of the sauna climate device must be performed by a qualified electrician. The unit must be permanently connected with a cable that is suited for the tempera
-
ture conditions of the environment. A protective earth (PE) connection with conductors of at least 2.5 mm2 must be connected to the connection terminal of the device.
The power for the device must be taken from the power circuit of the control device, which is protected by overcurrent fuses. The required sizes of overcurrent fuses and
connection cable dimensions are given in
Table 1
(page 16). All certified sauna controller devices with the sufficient capacity for the Saunum H-1 model in accordance with
Table 1 (page 16) can be used to control the sauna climate device.
Before beginning installation, read the installation instructions and pay attention to the following:
• Power and type of heater are suitable for the given steam room. The recommended steam room volume is given in
Table 1
(page 16).
• The supply voltage is suitable for the sauna climate device.
• The minimum installation safety distances measured from the heater housing at the installation location of the sauna climate device meet therequirements
specified in table
• The dimensions of the device are shown in
Figure 3.1
.
• Also, make sure that the upper edge of the fan outlet of the sauna climate device is lower than the lower edge of the bench. There must be no obstructions in
front of the air outlet of the device; the exhaust air stream must be able to circulate freely over the steam room.
The device works most effectively when its flue cap is mounted to the ceiling of the steam room and the exhaust air is blown under the bench. However, the device must
not be positioned so that the upper edge of the heater is higher than 80 cm from the floor. The device is designed for wall mounting with 6 mm (lower part) and 5 mm
(flue cap) bolts. At the installation site of a sauna climate device, the wall must withstand the weight of the device (at least 80 kg). The type of anchor bolts should be
selected according to the characteristics of the load-bearing structure at the installation site. The method of mounting must ensure that the device remains firmly on the
wall.
The safety distance requirements must be complied with unconditionally, as failure to do so will result in a fire hazard.
Only one sauna climate device may be installed in the steam room.
3.2. Wall mounting of the sauna climate unit.
See Figures 3.2 to 3.8.
3.2.1.
Loosen the four fixing screws holding the flue socket and remove the flue socket (
Figure 3.2
).
3.2.2
Turn the bolts in the middle fixing holes of the wall leaving them unturned by 5 mm (
Figure 3.3
).
3.2.3.
Then, lift the device on the wall so that the bolts in the wall slide into the openings on the back of the device (
Figure 3.4
).
3.2.4.
Screw the fixing bolts into the upper and lower mounting holes and secure the unit to the wall, then tighten the lower mounting bolts to the end (
Figure 3.5
).
3.2.5.
Put the flue socket back and secure with four screws (
Figure 3.6
).
3.2.6.
Attach the flue cap under the sauna room ceiling using two 5 mm bolts (
Figure 3.7
). NB! Align the flue cap with the flue opening in the flue socket!.
3.2.7.
Put the lower end of the flue on the flue socket.
3.2.8.
Hang the upper part of the flue to the flue cap so that the upper part of the flue is connected to the lower part of the flue (
Figure 3.8
).
3.2.9.
Connect the sauna climate device to the control device (
Section 3.3
).
3.2.10.
Fill the stone room of the sauna climate device with heater stones (
Section 1.6
).
Содержание H-1/6
Страница 1: ...1...
Страница 2: ...Saunum s climate system devices H 1 6 and H 1 9 for saunas Instructions for use and installation...
Страница 4: ...4 Saunum Saunas LTD congrats you on choosing an innovative sauna climate device...
Страница 22: ...22 2 2 3 3 1 1 Figure 3 8 Fitting the flue to the flue socket and hanging it to the flue cap FIGURES...
Страница 23: ...23 Figure 4 Opening electrical panel FIGURES...
Страница 24: ...24 Figure 5 Opening himalayan salt ball shelf FIGURES...
Страница 25: ...25 Placing heating element supporting rods and placing stones in the stove FIGURES...