The housing of the device may be cleaned with a cloth dampened with water. Do not use high pressure washers and running water for cleaning! Do not use chemical 

detergents or solvents for cleaning! To remove limescale stains from the sauna climate device, use 10% citric acid solution and rinse with clean water. Excessive dirt 

can unbalance the fan rotor, which in turn leads to an increase in noise when the sauna climate device is operating. Noise can also increase as a result of damaging / 

bending the fan blades.

Make sure that no foreign objects or salt balls are in the fan rotor’s working area. Generally, the fan does not require cleaning more than once a year. 

Only a person authorised by Saunum can clean the fan. Using compressed air to clean the fan can permanently damage the fan rotor! 

The fan bearings are maintenance-free and must be replaced in case of malfunctions.

We recommend to check all electrical connections of the sauna climate device at least once a year. This may be performed by a qualified person.

2.  SAUNA ROOM

The sauna climate device is intended for installation in a properly prepared sauna room. Walls and ceilings must be isolated well, otherwise it will take too much time 

and energy to warm up the room. The power supply cables for the heater and fan of the sauna must be connected through the electrical supply connection box in 

accordance with Table 1 (page 16).

2.1. Ventilation of the sauna room

The air in the sauna room must be changed at least six times per hour. If mechanical air extraction is used, place the air supply above the sauna climate device. 

If natural air extraction is used, place the air supply under or next to the sauna climate device. The air inlet pipe must be 80 to 100 mm in diameter. Install an air 

outlet near the floor, as far from the sauna climate device as possible. The air exhaust pipe should be twice the diameter of the air inlet pipe. If the air extraction 

opening is in the washroom, there must be a gap of at least 100 mm under the steam room door. Extraction ventilation in the sauna room is mandatory. Optional 

venting hole for drying should be installed in the ceiling near the sauna climate device’s opposite wall (closed during heating and bathing). The sauna can also be 

dried by leaving thedoor open after using the sauna. The ventilation system of the sauna should preferably obstruct exhaust air of the sauna from getting into other 

rooms, especially if using the sauna climate device with salt balls.

2.2.  Power of heater

If there is sufficient isolation behind the wall and ceiling, the power of the heater will determine the volume of the sauna. Non-isolated walls (brick, glass block, glass, 

concrete, floor tiles, etc.) increase the power demand of the heater. Add 1.2 m³ to the volume of the sauna for each non-isolated square meter of wall. For example, 

a 10 m³ sauna room with a glass door corresponds to the capacity requirements of a 12 m³ sauna room. If the sauna room has log walls, multiply the volume 

measure by 1.5. The optimal size of the sauna for the Saunum PREMIUM Set H-1 is given in 

Table 1

 (page 16). The height of the sauna is usually 2100...2300 mm. 

When installing the sauna climate device Saunum H-1, the minimum height is 2100 mm.

Содержание H-1/6

Страница 1: ...1...

Страница 2: ...Saunum s climate system devices H 1 6 and H 1 9 for saunas Instructions for use and installation...

Страница 3: ...s of the following directives of the Council of Europe provided that the installation has been conducted pursuant to the installation instructions issued by the producerof the devices and the instruct...

Страница 4: ...4 Saunum Saunas LTD congrats you on choosing an innovative sauna climate device...

Страница 5: ...control unit shall have the capability to control the fan of the sauna climate device and preferably function to switch off the heater and the fan of the sauna climate device simultaneously To ensure...

Страница 6: ...reach the right temperature in a properly isolated sauna room The stones usually heat up to the steam temperature at the same time as the sauna room In order not to raise the surface temperature of th...

Страница 7: ...e time the bench does not become hot You can find the best setting for you by experimenting Start testing at lower temperatures and minimum airflow rates If the temperature rises too high during your...

Страница 8: ...ve the air outlet grille and place the salt balls in the recesses Figure 5 Do not use start up the device if the salt balls have gotten into the fan housing After installing or removing the salt balls...

Страница 9: ...air and humid climate can create oxide coating rust on the metal surfaces of the heater Make sure you have sufficient ventilation in the sauna room Saunum is not responsible for the potential corrosi...

Страница 10: ...s to reach the right temperature in a properly isolated sauna room Make sure the ventilation solution used is suitable for the sauna Reduce the fan speed of the sauna climate device The panel or other...

Страница 11: ...sauna climate device near the stone room or the fan 1 7 Maintenance Due to the large temperature fluctuations the heater stones tend to crumble The stones should be restacked at least once a year or...

Страница 12: ...echanical air extraction is used place the air supply above the sauna climate device If natural air extraction is used place the air supply under or next to the sauna climate device The air inlet pipe...

Страница 13: ...st air is blown under the bench However the device must not be positioned so that the upper edge of the heater is higher than 80 cm from the floor The device is designed for wall mounting with 6 mm lo...

Страница 14: ...powered from a 380 VAC 3 phase or 230 VAC 1 phase 50 60 Hz power supply via a control device protected by an overcurrent protector of the size shown in table 1 If the device s air circulation fan is...

Страница 15: ...15 400 290 290 100 525 750 750 230 max 2100mm DRAWING Figure 3 1 Premium sauna climate system overall dimensions...

Страница 16: ...ety distances of the sauna climate device and the recommended location in the steam room Sauna device Volume Saunum H 1 6 6kW 5 9 m3 Saunum H 1 9 9kW 8 15 m3 min 50mm min 75mm min 50mm min 100mm A A A...

Страница 17: ...mensions ELECTRIC PANEL STEAM ROOM CONTROL UNIT IP65 FAN HEATING ELEMENTS CONTROL PANEL TEMPERATURE SENSOR LOCATION ACCORDING TO THE MANUFACTURER S REQUIRMENTS DOOR SENSOR 2x 0 34mm 2 OPTIONAL Optiona...

Страница 18: ...1 9 CABLE mm2 3 phase 1phase fan SAFETY DISTANCE FROM THE HEATER SAUNA ROOM CUBIC VOL m3 ELECTRIC CIRCUIT DIAGRAM Table 1 DEVICE HOUSING POWER SPEED MOTOR FAN HOUSING HEATER blue yellow green 230 400V...

Страница 19: ...19 350 350 7 13 5 350 160 1 2 max 510mm min 310mm FIGURES Figure 3 2 Removing the flue socket Figure 3 3 Installing bolts for middle mounting holes...

Страница 20: ...20 4x M6 Figure 3 4 Hanging the sauna climate device on the wall Figure 3 5 Installing the upper and lower mounting bolts and fixing the sauna climate device to the wall FIGURES...

Страница 21: ...21 1 2 max 2100mm max 1500mm Figure 3 6 Installation of flue socket on the device and fastening with screws Figure 3 7 Fitting and fastening the flue cap FIGURES...

Страница 22: ...22 2 2 3 3 1 1 Figure 3 8 Fitting the flue to the flue socket and hanging it to the flue cap FIGURES...

Страница 23: ...23 Figure 4 Opening electrical panel FIGURES...

Страница 24: ...24 Figure 5 Opening himalayan salt ball shelf FIGURES...

Страница 25: ...25 Placing heating element supporting rods and placing stones in the stove FIGURES...

Отзывы: