![Saunier Duval THEMA F 23 E Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/saunier-duval/thema-f-23-e/thema-f-23-e_installation-and-servicing-instructions_1202905004.webp)
4
Burner injector
mm
1,20
1,20
1,20
Inlet pressure
mbar
20
20
20
Diaphragme
mm
—
—
—
Gas rate (maximum)
m
3
/h
2,70
2,17
2,70
Gas rate (minimum)
m
3
/h
1,13
1,13
1,13
Burner injector
mm
0,73
0,73
0,73
Inlet pressure
mbar
29
29
29
Diaphragme
mm
4,8
3,2
4,8
Gas rate (maximum)
kg/h
2,01
1,62
2,01
Gas rate (minimum)
kg/h
1,13
1,13
1,13
Burner injector
mm
0,73
0,73
0,73
Inlet pressure
mbar
37
37
37
Diaphragme
mm
4,8
3,2
4,8
Gas rate (maximum)
kg/h
1,98
1,60
1,98
Gas rate (minimum)
kg/h
0,97
0,97
0,97
Burner injector
mm
2,4
2,4
2,4
Inlet pressure
mbar
8
8
8
Diaphragme
mm
—
—
—
Gas rate (maximum)
m
3
/h
3,88
3,88
Gas rate (minimum)
m
3
/h
1,63
1,63
1,63
THEMA F 23 E
TECHNICAL DATA
THEMA F SB 18 E
THEMA F SB 23 E
Heating output
automatically variable from (kW)
8,9
8,9
8,9
(BTU/H)
30,000 30,000 30,000
to (kW)
23,3
18,5
23,3
(BTU/H)
80,000 63,000 80,000
Efficiency
(%)
91,5
90,5
91,5
Heating adjustment
38
°
C to 90
°
C
Expansion vessel effective capacity
(l)
6,5
6,5
6,5
Expansion vessel charge pressure
(bar)
0,5
0,5
0,5
Maximum system capacity at 75
°
C
(l)
160
160
160
Safety valve, maximum service pressure
(bar)
3
3
3
Products outlet diameter
( mm)
60
60
60
Fresh air inlet diameter
(mm)
100
100
100
Hot water output
automatically variable from (kW)
8,9
—
—
(BTU/H)
30,000
—
—
to (kW)
23,3
—
—
(BTU/H)
80,000
—
—
Maximum hot water temperature
(
°
C)
65
—
—
Specific flow rate (for 30
°
C temp rise)
( l/min)
9,6
—
—
Threshold flow rate
(l/min)
3
—
—
Nominal water flow rate
(l/min)
12
—
—
Maximum supply pressure
(bar)
10
—
—
Minimum operating pressure
(bar)
0,5
—
—
Electrical supply
(V)
230
230
230
Maximum absorbed power
(W
150
150
150
Natural Gas
(G20)
Butane
(G30)
Pr
opane
(G31)
Town gas
(G130)
Содержание THEMA F 23 E
Страница 28: ...28 108198 B 06 98...